Evidence map›Paper›PMID 31262001›Full record

ArticleBiosensors2019

Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients' Sera.

Dan Tao, Bingqing Shui, Yingying Gu, Jing Cheng, Weiying Zhang, Nicole Jaffrezic-Renault, Shizhen Song, Zhenzhong Guo

Erratum issuedAbstract read
In one paragraph

Article in Biosensors, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Article
  16. Review
  17. Review
  18. Review
  19. Review
  20. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Dan TaoHubei Province Key Laboratory of Occupational Hazard Identification and Control, Medical College, Wuhan University of Science and Technology, Wuhan 430065, China.
Bingqing ShuiHubei Province Key Laboratory of Occupational Hazard Identification and Control, Medical College, Wuhan University of Science and Technology, Wuhan 430065, China.
Yingying GuHubei Province Key Laboratory of Occupational Hazard Identification and Control, Medical College, Wuhan University of Science and Technology, Wuhan 430065, China.
Jing ChengHubei Province Key Laboratory of Occupational Hazard Identification and Control, Medical College, Wuhan University of Science and Technology, Wuhan 430065, China.
Weiying ZhangKey Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, Institute for Interdisciplinary Research, Jianghan University, Wuhan 430056, China.
Nicole Jaffrezic-RenaultUniversity of Lyon, Institute of Analytical Sciences, UMR-CNRS 5280, 5, La Doua Street, 69100 Villeurbanne, France. nicole.jaffrezic@univ-lyon1.fr.ORCID 0000-0003-1354-9273
Shizhen SongResources and Environmental Engineering College, Wuhan University of Science and Technology, Wuhan 430081, China. songshizhen@wust.edu.cn.
Zhenzhong GuoHubei Province Key Laboratory of Occupational Hazard Identification and Control, Medical College, Wuhan University of Science and Technology, Wuhan 430065, China. zhongbujueqi@hotmail.com.

Funding

Nicole Jaffrezic-Renault IRN # 0876Zhenzhong Guo 090227
6 · The paper itself

Abstract

The electrochemical aptamer sensor has been designed for detecting tau381, a critical biomarker of Alzheimer's disease in human serum. The aptasensor is obtained by immobilizing the aptamer on a carboxyl graphene/thionin/gold nanoparticle modified glassy-carbon electrode. As a probe and bridge molecule, thionin connected carboxyl graphene and gold nanoparticles, and gave the electrical signal. Under optimal conditions, the increment of differential pulse voltammetry signal increased linearly with the logarithm of tau381 concentration in the range from 1.0 pM to 100 pM, and limit of detection was 0.70 pM. The aptasensor reliability was evaluated by determining its selectivity, reproducibility, stability, detection limit, and recovery. Performance analysis of the tau381 aptasensor in 10 patients' serum samples showed that the aptasensor could screen patients with and without Alzheimer's disease. The proposed aptasensor has potential for use in clinically diagnosing Alzheimer's disease in the early stage.

Indexed as

Biosensing TechniquesElectrochemical TechniquesSELEX Aptamer TechniqueAlzheimer DiseaseElectrodesGoldGraphiteHumansLimit of DetectionMetal NanoparticlesMutant ProteinsReproducibility of ResultsTauopathiestau ProteinsGoldGraphiteMutant Proteinstau ProteinsAlzheimer′s diseaseaptasensorcarboxyl graphene/thionin/gold nanoparticleshuman serumtau381

Identifiers

PMID31262001
PMCPMC6784373

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.