ArticleTranslational vision science & technology2019
Reproducibility of Measurements of Retinal Structural Parameters Using Optical Coherence Tomography in Stargardt Disease.
Article in Translational vision science & technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 24 citations in OpenAlex.
- Characterization of the Subclinical Perilesional Zone in the Macula of Early-Stage ABCA4 Disease.Translational vision science & technology · 2025Article
- Photoreceptor Disease at Ambiguous Transition Zones in Inherited Retinal Degenerations.Translational vision science & technology · 2025Article
- Advances in machine learning for ABCA4-related retinopathy: segmentation and phenotyping.International ophthalmology · 2025Review
- Looking outside the box with a pathology aware AI approach for analyzing OCT retinal images in Stargardt disease.Scientific reports · 2025Article
- Photoreceptor assessment in age-related macular degeneration.Eye (London, England) · 2025Review
- Recurrent and Concurrent Prediction of Longitudinal Progression of Stargardt Atrophy and Geographic Atrophy.medRxiv : the preprint server for health sciences · 2024Article
- Volume-accumulated reflectivity of the outer retina (integral) on spectral domain optical coherence tomography as a predictor of cone cell density: a pilot study.BMC ophthalmology · 2023Article
- Structural evaluation in inherited retinal diseases.The British journal of ophthalmology · 2021Review
- Clinical spectrum, genetic complexity and therapeutic approaches for retinal disease caused by ABCA4 mutations.Progress in retinal and eye research · 2020Review
- Analysis of retinal sublayer thicknesses and rates of change in ABCA4-associated Stargardt disease.Scientific reports · 2020Observational
- Retinal Boundary Segmentation in Stargardt Disease Optical Coherence Tomography Images Using Automated Deep Learning.Translational vision science & technology · 2020Article
- The role of multimodal imaging and vision function testing inTherapeutic advances in ophthalmologyReview
- Censoring the Floor Effect in Long-Term Stargardt Disease Microperimetry Data Produces a Faster Rate of Decline.Ophthalmology scienceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 7 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo assess the reproducibility of retinal measurements from optical coherence tomography (OCT) in
methodsThe international multicenter Progression of Atrophy Secondary to Stargardt Disease (ProgStar) Study enrolled 259 STGD1 patients. OCT images were graded by the study reading center (RC). Semiautomatic segmentation with manual adjustments was used to segment the layers of retinal pigmentation epithelium, outer segments, inner segments (ISs), outer nuclear layer (ONL), inner retina, and the total retina (TR). The images were overlaid to the Early Treatment Diabetic Retinopathy Study (ETDRS) grid. For each layer, the thickness and the intact area of the ETDRS central subfield, inner ring, and outer ring were recorded, respectively. A different set of RC graders regraded 30 independent ProgStar images to evaluate measurement reproducibility. Reproducibility was assessed graphically and using statistics including intraclass correlation (ICC) and relative absolute difference (RAD).
resultsAcross all layers, measurements of the ETDRS central subfield had low ICC and/or large RAD. The outer-ring region was not fully captured in some images. For inner ring, good reproducibility was observed for intact area in the IS (ICC = 0.99, RAD = 4%), thicknesses of the ONL (ICC = 0.93, RAD = 6%), and TR (ICC = 0.99, RAD = 1%).
conclusionsSTGD1's complex morphology made outer retina segmentation challenging. Measurements of the inner ring, including the intact area of IS (i.e., the ellipsoid zone [EZ]) and ONL and TR thicknesses, had good reproducibility and showed anatomical impairment. TRANSLATIONAL RELEVANCE: ONL and TR thicknesses and the EZ intact area in the ETDRS inner ring hold potential as structural endpoints for STGD1 trials. Structure-function relationships need to be further established.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials