ArticleJournal of hospital medicine2019
Recommendations on the Use of Ultrasound Guidance for Adult Lumbar Puncture: A Position Statement of the Society of Hospital Medicine.
Article in Journal of hospital medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed, 102 citations in OpenAlex.
- Accuracy of ultrasound-guided lumbar vertebral level identification: a comparative study with palpation in elderly patients with spinal deformities.Journal of medical ultrasonics (2001) · 2026Trial
- Accuro ultrasound-based system with computer-aided image interpretation compared to traditional palpation technique for neuraxial anesthesia placement in obese parturients undergoing cesarean delivery: a randomized controlled trial.Journal of anesthesia · 2021Trial
- Ultrasound-Assisted Lumbar Puncture: A Narrative Review With Implications for Educators in the Clinical Neurosciences.Neurology. Education · 2026Review
- Accuracy of Palpation-Guided Versus First Attempt at Ultrasound-Guided Electromyography Needle Placement for the Extensor Carpi Radialis Longus and Brevis by Trainees.Muscle & nerve · 2026Article
- Point-of-Care Ultrasound Guidelines From Family Medicine, Emergency Medicine, and Internal Medicine for Curriculum Development: A Narrative Review.Journal of graduate medical education · 2026Review
- Increased lumbar puncture success using a paramedian approach: A retrospective cohort study.Journal of hospital medicine · 2026Article
- uSINE-PAMS Artificial Intelligence-Driven, Ultrasound-Guided Lumbar Puncture to Improve Procedural Accuracy: A Pilot Study Report.Neurology. Clinical practice · 2025Article
- Assessing the clinical relevance of point-of-care ultrasound for hospitalists: Influence on clinical reasoning and decision-making.PloS one · 2025Article
- Article
- 'UltraGUD LP'-ultrasound guided diagnostic LP-a randomizedcontrolled trial. Traditional landmark based lumbar puncture is as effective as ultrasound guided lumbar puncture in outpatient neurology settings.Frontiers in neurology · 2025Article
- Comparison of 6 handheld ultrasound devices by point-of-care ultrasound experts: a cross-sectional study.The ultrasound journal · 2024Article
- Lumbar Puncture Complications: A Review of Current Literature.Current pain and headache reports · 2024Review
- Wearable Mechatronic Ultrasound-integrated AR Navigation System for Lumbar Puncture Guidance.IEEE transactions on medical robotics and bionics · 2023Article
- Point-of-Care Ultrasound: A Multimodal Tool for the Management of Sepsis in the Emergency Department.Medicina (Kaunas, Lithuania) · 2023Review
- Ultrasound in Sepsis and Septic Shock-From Diagnosis to Treatment.Journal of clinical medicine · 2023Review
- Association of Internal Medicine Point of Care Ultrasound (POCUS) with Length of Stay, Hospitalization Costs, and Formal Imaging: a Prospective Cohort Study.POCUS journal · 2023Article
- Development of a Point-of-Care Ultrasound Track for Internal Medicine Residents.Journal of general internal medicine · 2022Article
- Multimodal Diagnostic Approaches to Advance Precision Medicine in Sarcopenia and Frailty.Nutrients · 2022Review
- Motivations, barriers, and professional engagement: a multisite qualitative study of internal medicine faculty's experiences learning and teaching point-of-care ultrasound.BMC medical education · 2022Article
- State-of-the-art of lumbar puncture and its place in the journey of patients with Alzheimer's disease.Alzheimer's & dementia : the journal of the Alzheimer's Association · 2022Review
Corrections and comments
- Commented on by
Authors and funding
14 authors at 11 institutions in 1 country.
Funding
Abstract
executive summaryWhen ultrasound equipment is available, along with providers who are appropriately trained to use it, we recommend that ultrasound guidance should be used for site selection of lumbar puncture to reduce the number of needle insertion attempts and needle redirections and increase the overall procedure success rates, especially in patients who are obese or have difficult-to-palpate landmarks. We recommend that ultrasound should be used to more accurately identify the lumbar spine level than physical examination in both obese and nonobese patients. We suggest using ultrasound for selecting and marking a needle insertion site just before performing lumbar puncture in either a lateral decubitus or sitting position. The patient should remain in the same position after marking the needle insertion site. We recommend that a low-frequency transducer, preferably a curvilinear array transducer, should be used to evaluate the lumbar spine and mark a needle insertion site. A high-frequency linear array transducer may be used in nonobese patients. We recommend that ultrasound should be used to map the lumbar spine, starting at the level of the sacrum and sliding the transducer cephalad, sequentially identifying the lumbar spine interspaces. We recommend that ultrasound should be used in a transverse plane to mark the midline of the lumbar spine and in a longitudinal plane to mark the interspinous spaces. The intersection of these two lines marks the needle insertion site. We recommend that ultrasound should be used during a preprocedural evaluation to measure the distance from the skin surface to the ligamentum flavum from a longitudinal paramedian view to estimate the needle insertion depth and ensure that a spinal needle of adequate length is used. We recommend that novices should undergo simulation-based training, where available, before attempting ultrasound-guided lumbar puncture on actual patients. We recommend that training in ultrasound-guided lumbar puncture should be adapted based on prior ultrasound experience, as learning curves will vary. We recommend that novice providers should be supervised when performing ultrasound-guided lumbar puncture before performing the procedure independently on patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.