Evidence map›Paper›PMID 31248048›Full record

ArticleInternational journal of environmental research and public health2019

Experimental Method of Emission Generation Calibration Based on Reference Liquids Characterization.

Sébastien Soulet, Marie Duquesne, Jean Toutain, Charly Pairaud, Hélène Lalo

Abstract read
In one paragraph

Article in International journal of environmental research and public health, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Impact of Vaping Regimens on Electronic Cigarette Efficiency.International journal of environmental research and public health · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sébastien SouletLaboratoire Français du E-Liquide, 218 avenue du Haut-Levêque, 33600 Pessac, France. sebastien.soulet@lfel.fr.
Marie DuquesneBordeaux INP, CNRS, I2M Bordeaux, ENSCBP, 16 avenue Pey Berland, 33607 Pessac CEDEX, France.ORCID 0000-0002-9249-8613
Jean ToutainBordeaux INP, CNRS, I2M Bordeaux, ENSCBP, 16 avenue Pey Berland, 33607 Pessac CEDEX, France.ORCID 0000-0002-9891-3582
Charly PairaudLaboratoire Français du E-Liquide, 218 avenue du Haut-Levêque, 33600 Pessac, France.
Hélène LaloLaboratoire Français du E-Liquide, 218 avenue du Haut-Levêque, 33600 Pessac, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This work focuses on an experimental study of the influence of e-liquid composition on the mass of vaporized e-liquid after standardized emission generation using a U-SAV (Universal System for Analysis of Vaping) vaping machine. All the experiments were based on the use of a Cubis 1Ω clearomiser and on the standard protocol for electronic cigarettes emission generation. Currently, there is no standardized method available to calibrate the emission generations of electronic cigarettes. Since the e-liquid compositions are not always known, we propose a simple, practical, effective, and fast method of emission generation calibration. Therefore, this paper examines a major issue in this new and constantly evolving field, allowing the validation of the emission generation results. To our knowledge, this method is a novelty in our discipline and could be easily developed in laboratories. Pure propylene-glycol, glycerol, ethanol, and water and their mixtures (20 e-liquids) were tested as reference materials, allowing an e-liquids benchmarking and the characterization of 800 commercial e-liquids (with known and unknown compositions) at a fixed power and for one inhalation profile (3 s puff duration and 55 mL of puff volume). The influence of ethanol and/or water addition in the e-liquid was characterized.

Indexed as

Electronic Nicotine Delivery SystemsCalibrationEthanolGlycerolPropylene GlycolReference ValuesWaterEthanolGlycerolPropylene GlycolWaterdensityelectronic cigaretteE-liquid benchmarkinge-liquid compositionemission generationstandardizationvaporization

Identifiers

PMID31248048
PMCPMC6651204

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.