SPARE: Sparse-view reconstruction challenge for 4D cone-beam CT from a 1-min scan.
Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
39 citing papers in PubMed.
- DiffINR: conditional neural field diffusion for deformation-driven volumetric image estimation from limited measurements.Physics in medicine and biology · 2026Article
- 'See' through the surface: surface-derived three-dimensional AI-driven real-time imaging solution for intra-treatment image guidance.Machine Learning. Health · 2026Article
- Clinical feasibility of fast adaptive four-dimensional cone-beam computed tomography for lung cancer radiotherapy.Physics and imaging in radiation oncology · 2026Article
- Dynamic cone beam CT reconstruction via spatiotemporal Gaussian neural representation.Medical physics · 2025Article
- A hybrid population-based and patient-specific framework for 2D-3D deformable registration-driven limited-angle cone-beam CT estimation.Medical physics · 2025Article
- Prior-adapted progressive time-resolved CBCT reconstruction using a dynamic reconstruction and motion estimation method.Medical physics · 2025Article
- Time-resolved dynamic CBCT reconstruction using prior-model-free spatiotemporal Gaussian representation (PMF-STGR).Physics in medicine and biology · 2025Article
- Article
- An open-source deep learning framework for respiratory motion monitoring and volumetric imaging during radiation therapy.Medical physics · 2025Article
- Real-time spatiotemporal optimization during imaging.Communications engineering · 2025Article
- Real-time CBCT imaging and motion tracking via a single arbitrarily-angled x-ray projection by a joint dynamic reconstruction and motion estimation (DREME) framework.Physics in medicine and biology · 2025Article
- Machine Learning-Based X-Ray Projection Interpolation for Improved 4D-CBCT Reconstruction.IEEE open journal of engineering in medicine and biology · 2025Article
- Probabilistic 3D Correspondence Prediction from Sparse Unsegmented Images.Machine learning in medical imaging. MLMI (Workshop) · 2025Article
- Fast motion-compensated reconstruction for 4D-CBCT using deep learning-based groupwise registration.Biomedical physics & engineering express · 2024Article
- Monte Carlo-based simulation of virtual 3 and 4-dimensional cone-beam computed tomography from computed tomography images: An end-to-end framework and a deep learning-based speedup strategy.Physics and imaging in radiation oncology · 2024Article
- Article
- Dynamic CBCT imaging using prior model-free spatiotemporal implicit neural representation (PMF-STINR).Physics in medicine and biology · 2024Article
- Spectral CT image reconstruction using a constrained optimization approach-An algorithm for AAPM 2022 spectral CT grand challenge and beyond.Medical physics · 2024Article
- Reducing image artifacts in sparse projection CT using conditional generative adversarial networks.Scientific reports · 2024Article
- Surrogate-driven respiratory motion model for projection-resolved motion estimation and motion compensated cone-beam CT reconstruction from unsorted projection data.Physics in medicine and biology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
purposeCurrently, four-dimensional (4D) cone-beam computed tomography (CBCT) requires a 3-4 min full-fan scan to ensure usable image quality. Recent advancements in sparse-view 4D-CBCT reconstruction have opened the possibility to reduce scan time and dose. The aim of this study is to provide a common framework for systematically evaluating algorithms for 4D-CBCT reconstruction from a 1-min scan. Using this framework, the AAPM-sponsored SPARE Challenge was conducted in 2018 to identify and compare state-of-the-art algorithms.
methodsA clinically realistic CBCT dataset was simulated using patient CT volumes from the 4D-Lung database. The selected patients had multiple 4D-CT sessions, where the first 4D-CT was used as the prior CT, and the rest were used as the ground truth volumes for simulating CBCT projections. A GPU-based Monte Carlo tool was used to simulate the primary, scatter, and quantum noise signals. A total of 32 CBCT scans of nine patients were generated. Additional qualitative analysis was performed on a clinical Varian and clinical Elekta dataset to validate the simulation study. Participants were blinded from the ground truth, and were given 3 months to apply their reconstruction algorithms to the projection data. The submitted reconstructions were analyzed in terms of root-mean-squared-error (RMSE) and structural similarity index (SSIM) with the ground truth within four different region-of-interests (ROI) - patient body, lungs, planning target volume (PTV), and bony anatomy. Geometric accuracy was quantified as the alignment error of the PTV.
resultsTwenty teams participated in the challenge, with five teams completing the challenge. Techniques involved in the five methods included iterative optimization, motion-compensation, and deformation of the prior 4D-CT. All five methods rendered significant reduction in noise and streaking artifacts when compared to the conventional Feldkamp-Davis-Kress (FDK) algorithm. The RMS of the three-dimensional (3D) target registration error of the five methods ranged from 1.79 to 3.00 mm. Qualitative observations from the Varian and Elekta datasets mostly concur with those from the simulation dataset. Each of the methods was found to have its own strengths and weaknesses. Overall, the MA-ROOSTER method, which utilizes a 4D-CT motion model for temporal regularization, had the best and most consistent image quality and accuracy.
conclusionThe SPARE Challenge represents the first framework for systematically evaluating state-of-the-art algorithms for 4D-CBCT reconstruction from a 1-min scan. Results suggest the potential for reducing scan time and dose for 4D-CBCT. The challenge dataset and analysis framework are publicly available for benchmarking future reconstruction algorithms.