Evidence map›Paper›PMID 31247046›Full record

ArticlePloS one2019

Battery-operated portable PCR system with enhanced stability of Pt RTD.

Juhun Lim, Sangdo Jeong, Miyoung Kim, Jong-Hyun Lee

Abstract readEvaluation Study
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review of methods for the detection ofJournal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc · 2021
    Review
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Juhun LimDepartment of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, Republic of Korea.ORCID 0000-0001-8874-7616
Sangdo JeongDepartment of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, Republic of Korea.
Miyoung KimSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, Republic of Korea.
Jong-Hyun LeeDepartment of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper reports an outdoor-use polymerase chain reaction (PCR) technology in which stability of resistance temperature detectors (RTDs) is remarkably improved. A thin-film RTD made of non-annealed Pt shows accuracy degradation because the resistance of the RTD tends to decrease during the PCR operation. Thus, the annealing process is applied to the Pt RTD to improve the stability, which is a prerequisite to the accurate measurement of the absolute temperature. Both heaters and the RTD are fabricated on a thin quartz substrate whose melting temperature is high enough for annealing. The performances in the PCR time and power consumption are enhanced by reducing the size of the heater chips with no degradation in the temperature uniformity. A spring-loaded electrode is employed to simplify the procedure of electrical connection to the thermal controller and loading/unloading of the PCR chip. The contact area of the electrical connection is so small that the conductive thermal resistance increases; thereby small heat dissipation can be exploited for low-power operation. The stability of the RTD is experimentally confirmed in terms of resistance variation over repeated PCR operations (four times). The least variation of 0.005%, which corresponds to a negligible temperature variation of 0.038 °C for the PCR, is achieved from the RTD annealed for 5 min at 450 °C. The gel-electrophoresis result indicates that the PCR performance of the proposed system using a film-type PCR chip is comparable to that of a conventional system using a vial tube despite its low power consumption.

Indexed as

Computer SimulationDNA, BacterialElectric ImpedanceElectric Power SuppliesElectrophoresisEquipment DesignEscherichia coliHumansPlatinumPolymerase Chain ReactionTemperatureDNA, BacterialPlatinum

Identifiers

PMID31247046
PMCPMC6597155

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.