ArticlePloS one2019
Battery-operated portable PCR system with enhanced stability of Pt RTD.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Review
- Advances in Simple, Rapid, and Contamination-Free Instantaneous Nucleic Acid Devices for Pathogen Detection.Biosensors · 2023Review
- Article
- A Thermocycler Using a Chip Resistor Heater and a Glass Microchip for a Portable and Rapid Microchip-Based PCR Device.Micromachines · 2022Article
- Review of methods for the detection ofJournal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc · 2021Review
- Review
- Towards PCB-Based Miniaturized Thermocyclers for DNA Amplification.Micromachines · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper reports an outdoor-use polymerase chain reaction (PCR) technology in which stability of resistance temperature detectors (RTDs) is remarkably improved. A thin-film RTD made of non-annealed Pt shows accuracy degradation because the resistance of the RTD tends to decrease during the PCR operation. Thus, the annealing process is applied to the Pt RTD to improve the stability, which is a prerequisite to the accurate measurement of the absolute temperature. Both heaters and the RTD are fabricated on a thin quartz substrate whose melting temperature is high enough for annealing. The performances in the PCR time and power consumption are enhanced by reducing the size of the heater chips with no degradation in the temperature uniformity. A spring-loaded electrode is employed to simplify the procedure of electrical connection to the thermal controller and loading/unloading of the PCR chip. The contact area of the electrical connection is so small that the conductive thermal resistance increases; thereby small heat dissipation can be exploited for low-power operation. The stability of the RTD is experimentally confirmed in terms of resistance variation over repeated PCR operations (four times). The least variation of 0.005%, which corresponds to a negligible temperature variation of 0.038 °C for the PCR, is achieved from the RTD annealed for 5 min at 450 °C. The gel-electrophoresis result indicates that the PCR performance of the proposed system using a film-type PCR chip is comparable to that of a conventional system using a vial tube despite its low power consumption.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.