ArticleBMC gastroenterology2019
The potential role of CT enterography and gastrointestinal ultrasound in the evaluation of anti-tubercular therapy response of intestinal tuberculosis: a retrospective study.
Article in BMC gastroenterology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Dual-Energy CT Enterography in Intestinal Tuberculosis: Role of Relative Enhancement Calculated on Iodine Maps in Assessing Disease Activity.The Indian journal of radiology & imaging · 2026Article
- An Integrated Review of Conventional and Emerging Diagnostic and Therapeutic Modalities to Reduce the Risk of Surgical Resections in Intestinal Tuberculosis.Diagnostics (Basel, Switzerland) · 2026Review
- The Overlap Between Crohn's Disease and Intestinal Tuberculosis: A Never-Ending Story.Medicina (Kaunas, Lithuania) · 2026Review
- Tips and tricks for a proper radiological assessment of abdominal and pelvic lymph nodes.Abdominal radiology (New York) · 2024Review
- Gastrointestinal Ultrasound in Infectious Diseases: A Comprehensive Review.Medicina (Kaunas, Lithuania) · 2024Review
- Comments and Illustrations of Ultrasound Findings in Extrapulmonary Tuberculosis Manifestations.Diagnostics (Basel, Switzerland) · 2024Review
- Differentiating gastrointestinal tuberculosis and Crohn's disease- a comprehensive review.BMC gastroenterology · 2023Review
- Intestinal Tuberculosis Presenting with Gastrointestinal Bleeding in Patient on Warfarin Therapy.Case reports in gastrointestinal medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
backgroundAccurate evaluation of anti-tubercular therapy (ATT) responses is crucial for both diagnosis and treatment of intestinal tuberculosis (ITB). Little is known about the role of cross-sectional imaging techniques in ITB follow-up assessment. We aimed to investigate the accuracy of cross-sectional imaging modalities, CT enterography (CTE) and gastrointestinal ultrasound (GIUS), in the evaluation of ATT responses in ITB patients.
methodsPatients diagnosed with ITB and followed up by CTE and/or GIUS were retrospectively searched in the databases. Clinical, imaging, laboratory and endoscopic data were collected at baseline and the first follow-up visit. Responses were graded as good, partial and no response based on protocols described in the literature and by our institution. CTE evaluation was based on changes in the lesion area, mural thickness, enhancement patterns and lymph nodes, while GIUS evaluation was based on changes in bowel wall morphology and the Limberg score. Clinical evaluation was used as the gold-standard evaluation method, which was determined by a comprehensive impression of endoscopic changes along with symptomatic improvement and laboratory tests, with imaging results masked.
resultsTwenty patients with ITB were enrolled in our study. The first follow-up time was from 2 to 12 months (average 6 months). According to the gold standard evaluation, 11 patients were evaluated as having a good ATT response, while 9 had a partial response. A total of 18 patients were followed up by CTE, while 7 were followed up by GIUS, depending on medical and/or financial considerations. The accuracy of CTE and GIUS was 83% (15/18) and 85.7% (6/7), respectively. The sensitivity, specificity, PPV and NPV of CTE were 88.9, 77.8, 80 and 87.5%, respectively. Moreover, the sensitivity, specificity, PPV and NPV of GIUS were 100, 50, 83.3 and 100%, respectively. By combining the results of CTE and GIUS results, the overall accuracy was 90%, with sensitivity and specificity of 91.7 and 87.5%, respectively.
conclusionTo our knowledge, this is the first study exploring the accuracy of the cross-sectional imaging modalities CTE/GIUS in the evaluation of ATT responses. Our results indicated their promising application prospect in clinical practice as a non-invasive and cost-effective approach.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.