Evidence map›Paper›PMID 31242198›Full record

ArticlePloS one2019

Influence of silver nanoparticle solution on the mechanical properties of resin cements and intrarradicular dentin.

Thaís Yumi Umeda Suzuki, Juno Gallego, Wirley Gonçalves Assunção, André Luiz Fraga Briso, Paulo Henrique Dos Santos

Abstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
  14. Review
  15. Review
  16. Review
  17. Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Thaís Yumi Umeda SuzukiDepartment of Restorative Dentistry, Faculty of Dentistry, Federal University of Minas Gerais-UFMG, Belo Horizonte, MG, Brazil.ORCID 0000-0003-4220-3781
Juno GallegoDepartment of Mechanical Engineering, Engineering Faculty of Ilha Solteira, São Paulo State University, Ilha Solteira, SP, Brazil.
Wirley Gonçalves AssunçãoDepartment of Dental Materials and Prosthodontics, Aracatuba School of Dentistry, São Paulo State University, Araçatuba, SP, Brazil.
André Luiz Fraga BrisoDepartment of Restorative Dentistry, Aracatuba School of Dentistry, São Paulo State University, Araçatuba, SP, Brazil.
Paulo Henrique Dos SantosDepartment of Dental Materials and Prosthodontics, Aracatuba School of Dentistry, São Paulo State University, Araçatuba, SP, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study evaluated the influence of silver nanoparticle on mechanical properties of the components of underlying dentin and resin cement in different regions of intraradicular dentin. Ninety extracted single-rooted human teeth were used in this study. After endodontic preparation, the teeth were divided into five groups, according to the irrigating agents: distilled water, 5.25% sodium hypochlorite, 25% polyacrylic acid, 2% chlorhexidine and 23 ppm silver nanoparticles dispersion. Then, the groups were divided in 3 subgroups (n = 6) according to the technique adopted for adhesive cementation: SUA group: Scotchbond Universal Adhesive + RelyX ARC; U200 group: RelyX U200; and MCE group: MaxCem Elite. The mechanical properties of hardness and elastic modulus were measured in resin cement and underlying dentin in ultra-micro hardness tester in different thirds of radicular dentin surface. Data were subjected to ANOVA and Fisher's test (p = 0.05). In the underlying dentin, in general, there was no statistically significant difference in different thirds of intraradicular dentin according to the different solutions used. In the resin cements, higher hardness values were found, in general, for the cervical third. When silver nanoparticle solution was used, higher mechanical properties were generally obtained for resin cement for the SBU and U200 groups, with little or no changes in mechanical properties for the dentin. Silver nanoparticle application is a viable option for irrigation the intraradicular dentin previously through the cementation process of glass fiber posts. The mechanical properties are influenced by irrigant solutions used and the depth intraradical analyzed area.

Indexed as

CementationDentinMaterials TestingMetal NanoparticlesResin CementsRoot Canal PreparationSilverSurface PropertiesResin CementsSilver

Identifiers

PMID31242198
PMCPMC6594598

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.