Evidence map›Paper›PMID 31240377›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2020

Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes.

Kazumasa Yamamura, Yukihide Minoda, Ryo Sugama, Yoichi Ohta, Suguru Nakamura, Hideki Ueyama, Hiroaki Nakamura

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kazumasa YamamuraDepartment of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan.
Yukihide MinodaDepartment of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan. yminoda@msic.med.osaka-cu.ac.jp.
Ryo SugamaDepartment of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan.
Yoichi OhtaDepartment of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan.
Suguru NakamuraDepartment of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan.
Hideki UeyamaDepartment of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan.
Hiroaki NakamuraDepartment of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe accuracy of patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) is still controversial, especially in the tibial prosthesis. It was hypothesized that the design modification of PSI improved the tibial prosthetic alignment and reduced the associated complications. The aim of this study was to compare the accuracy of a conventional PSI with that of a newly designed PSI for total knee arthroplasty (TKA) using a new three-dimensional (3D) measurement method.

methodsThirty TKAs each using the conventional and newly designed PSIs were studied. The postoperative 3D-computed tomography (3D CT) image was superimposed on the preoperative 3D CT plan. The absolute differences in the tibial prosthetic alignment between the preoperative and postoperative 3D CT images were directly measured in the coronal, sagittal, and axial planes. Knees in which the difference in the prosthetic alignment was > 3° were considered deviations.

resultsThe new PSI showed less mean absolute differences and lower rate of deviations than the conventional PSI in the coronal and axial planes (p = 0.045 and p = 0.004, respectively). The deviations (> 3°) of the tibial prosthesis using the conventional PSI were 27, 30, and 63% and of those using the new PSI were 0, 20, and 20% in the coronal, sagittal, and axial planes, respectively.

conclusionsThis is the first report to evaluate the effect of improvement in PSI design on the postoperative alignment using 3D method, and it clearly showed that the modification significantly improved the accuracy of alignment and reduced the deviations. LEVEL OF EVIDENCE: Therapeutic study, case-control study, Level III.

Indexed as

Knee ProsthesisAgedArthroplasty, Replacement, KneeCase-Control StudiesFemaleHumansImaging, Three-DimensionalKnee JointMaleMiddle AgedOsteoarthritis, KneePatient-Specific ModelingProsthesis DesignSurgery, Computer-AssistedTibiaTomography, X-Ray ComputedPatient-specific instrumentationProsthetic alignmentThree-dimensional evaluationTotal knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.