ArticleBioMed research international2019
Systemic Level of Oxidative Stress during Orthodontic Treatment with Fixed Appliances.
Article in BioMed research international, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06507592 (In Vivo Evaluation of the Differences in Oxidative-reductive Processes in Saliva During Treatment With Conventional Brackets and Clear Aligners), which is not on this map. Cited by 15 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
In Vivo Evaluation of the Differences in Oxidative-reductive Processes in Saliva During Treatment With Conventional Brackets and Clear Aligners
Who cites it
15 citing papers in PubMed, 2 syntheses or guidelines pooled it, 25 citations in OpenAlex.
- Pooled it
- Oxidative Stress and Natural Products in Orthodontic Treatment: A Systematic Review.Nutrients · 2023Pooled it
- The Relationship Between Orthodontic Malocclusion Severity and Periodontal Clinical and Biochemical Parameters in Adolescents: A Cross-Sectional Study.Diagnostics (Basel, Switzerland) · 2026Article
- Article
- The regulatory role of oxidative stress in the tooth movement process of rats with chronic fluorosis.BMC oral health · 2025Article
- Xanthine oxidase inhibitor allopurinol preserves cardiac function after experimental malocclusion induced by occlusal disharmony in mice.The journal of physiological sciences : JPS · 2025Article
- Forastero cacao bean extract gel decreases IL-6 positive osteoblasts, osteoclasts, and osteocytes on OIRR model: A primitive study.Journal of Taibah University Medical Sciences · 2025Article
- Effects of coenzyme QClinical oral investigations · 2024Article
- Evaluation of Biomarkers of Bone Metabolism on Salivary Matrix in the Remodeling of Periodontal Tissue during Orthodontic Treatment.Dentistry journal · 2024Article
- Potential Uses ofJournal of pharmacy & bioallied sciences · 2023Review
- Salivary Markers of Oxidative Stress in Patients Undergoing Orthodontic Treatment with Clear Aligners versus Self-Ligating Brackets: A Non-Randomized Clinical Trial.Journal of clinical medicine · 2022Article
- Article
- Risk Assessment of Oxidative Stress Induced by Metal Ions Released from Fixed Orthodontic Appliances during Treatment and Indications for Supportive Antioxidant Therapy: A Narrative Review.Antioxidants (Basel, Switzerland) · 2021Review
- Effects of mechanical strain on periodontal ligament fibroblasts in presence of Aggregatibacter actinomycetemcomitans lysate.BMC oral health · 2021Article
- Are Metal Ions That Make up Orthodontic Alloys Cytotoxic, and Do They Induce Oxidative Stress in a Yeast Cell Model?International journal of molecular sciences · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aim of the study was to assess the level of selected systemic oxidative stress parameters during the first week of orthodontic treatment with fixed appliances. Fifty-four males with malocclusion and having a similar lifestyle were randomized using a computer based procedure and allocated to either the treatment group (TG; n=27;24.6 ± 1.7 years) or control group (CG; n=27;24.7 ± 1.7 years). Capillary blood was collected at baseline and 6 hours, 24 hours, and 7 days after archwire insertion. At the same time points, capillary blood was retrieved in the CG. In order to determine the oxidative stress, both the reactive oxygen species (ROS) formation and the antioxidative defense (AD) potential were measured using the ROS testing and oxygen free radicals defense (equivalent to antioxidant defense) testing, respectively, by a blinded operator. The ratio between ROS and AD (ROS/AD) was calculated and data were analyzed using nonparametric tests. No drop-outs or harms were detected. At baseline, neither ROS (1.54 [1.22; 2.12] and 1.74 [1.40; 2.01] for the TG and CG, respectively), AD (1.19 [0.66; 1.50] and 1.19 [0.57; 1.42] for the TG and CG, respectively), nor ROS/AD levels were significantly different (p>0.05). After 24 hours, the ROS level significantly increased in the TG (2.05 [1.71; 2.26]) and was higher compared to the CG ROS level (1.67 [1.29; 1.95]; p=0.025), while for the AD level, no marked between and within group differences were detected. A notable change of ROS/AD ratio was observed over time only within the TG (p=0.026). Moreover, a significantly higher ROS/AD ratio was detected 24 hours after archwire insertion in the TG compared to the CG (2.69 [1.44; 3.89] and 1.79 [1.45; 2.35], respectively), followed by a decrease. Orthodontic treatment with fixed appliances might induce systemic oxidative stress in the short-term, since ROS levels and ROS/AD levels are normalized within 7 days after archwire insertion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.