ArticleJournal of the mechanical behavior of biomedical materials2019
In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve.
Article in Journal of the mechanical behavior of biomedical materials, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 29 citations in OpenAlex.
- Design and Fabrication of 3D-Printed Biomimetic Fiber-Reinforced Polymeric Aortic Valves for Improved Stress Distribution.Annals of biomedical engineering · 2026Article
- Development and preclinical results of a transcatheter aortic valve implant with novel polymeric leaflets.NPJ cardiovascular health · 2026Article
- Advancements and Perspectives in the Bioprosthetic Heart Valve: A Comprehensive Review on Biomaterial Processing and Emerging Polymeric Materials.Journal of the American Heart Association · 2025Review
- Polymeric Heart Valves: Do They Represent a Reliable Alternative to Current Prosthetic Devices?Polymers · 2025Review
- Effects of implantation height on the performance of a redo transcatheter aortic valve replacement using a balloon-expandable valve.JTCVS open · 2024Article
- Analysis of the Effect of Thickness on the Performance of Polymeric Heart Valves.Journal of functional biomaterials · 2023Article
- Polymeric Heart Valves Will Displace Mechanical and Tissue Heart Valves: A New Era for the Medical Devices.International journal of molecular sciences · 2023Review
- Natural Polymers in Heart Valve Tissue Engineering: Strategies, Advances and Challenges.Biomedicines · 2022Review
- Hybrid membranes for the production of blood contacting surfaces: physicochemical, structural and biomechanical characterization.Biomaterials research · 2021Article
- Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.Annals of biomedical engineering · 2020Article
- In-vitro characterization of self-expandable textile transcatheter aortic valves.Journal of the mechanical behavior of biomedical materials · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Transcatheter aortic valve replacement (TAVR) is a life-saving alternative to surgical intervention. However, the identification of features associated with poor outcomes, including residual paravalvular leakage (PVL), leaflet calcification, and subclinical leaflet thrombosis, are cause to be concerned about valve durablilty (Mylotte and Piazza, 2015a, 2015b; Dasi et al., 2017; Makkar et al., 2015; Kheradvar et al., 2015a). The aim of this study is to optimize the potential of a hyaluronan (HA) enhanced polymeric transcatheter aortic valve (HA-TAV) that has promised to reduce blood damage causing-turbulent flow while maintaining durability. HA-enhanced linear low-density polyethylene (LLDPE) leaflets were sutured to novel cobalt chromium stents, size 26 mm balloon expandable stents. Hemodynamic performance was assessed in a left heart simulator under physiological pressure and flow conditions and compared to a 26 mm Medtronic Evolut and 26 mm Edwards SAPIEN 3. High-speed imaging and particle image velocimetry (PIV) were performed. The HA-TAV demonstrated an effective orifice area (EOA) within one standard deviation of the leading valve, SAPIEN 3.The regurgitant fraction (RF) of the HA-TAV (11.23 ± 0.55%) is decreased in comparison the Evolut (15.74 ± 0.73%) and slightly higher than the SAPIEN 3 (10.92 ± 0.11%), which is considered trace regurgitation according to valve standards. A decreased number of higher principal Reynolds shear stresses were shown for the HA-TAV at each cardiac phase. The HA-TAV is directly comparable and in some cases superior to the leading commercially available prosthetic heart valves in in-vitro hemodynamic testing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.