ArticleGastroenterology research2019
Revisiting the Reliability of the Endoscopy and Sedation-Assisted High-Resolution Esophageal Motility Assessment.
Article in Gastroenterology research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 11 citations in OpenAlex.
- Sedation and Endoscopy-Assisted High-Resolution Manometry (SEA-HRM) in Patients Who Previously Failed Standard Esophageal Manometry.Diagnostics (Basel, Switzerland) · 2024Article
- Nasopharyngeal airway assistance improves esophageal intubation rates of high-resolution esophageal manometry catheters.Neurogastroenterology and motility · 2024Article
- Technical Success in Performing Esophageal High-Resolution Manometry in Patients with an Epiphrenic Diverticulum.Dysphagia · 2024Article
- Nasal trumpet harmoniously improves tolerance to high-resolution impedance manometry catheter placement.Neurogastroenterology and motility · 2022Article
- A Comparative Assessment of the Diagnosis of Swallowing Impairment and Gastroesophageal Reflux in Canines and Humans.Frontiers in veterinary science · 2022Review
- Performing High-resolution Impedance Manometry After Endoscopy With Conscious Sedation Has Negligible Effects on Esophageal Motility Results.Journal of neurogastroenterology and motility · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundEsophageal high-resolution manometry (HRM) is performed for evaluation of dysphagia or the pre-operative evaluation before esophageal surgery. The esophageal manometry parameters, interpreted as per the Chicago classification (CC), are meant to be acquired in an awake state. At times, the patient intolerance or inability to traverse the manometry catheter across the esophagogastric junction (EGJ) renders incomplete esophageal motility evaluation; hence, sedation or endoscopy assistance is required. There have been concerns raised regarding the use of sedation and resultant alteration of the manometry parameters. The aims were to study the effects of intravenous sedation on esophageal motility parameters and analyze its impact on outcomes of patients with dysphagia who are intolerant to awake manometry procedure.
methodsThe study population comprised patients who had sedation or the endoscopy assistance for the HRM. The indication for HRM, necessity for the sedation, manometry findings, barium esophagogram results, procedural timings and patient outcomes were reviewed. The diagnostic impact of the 10% correction in integrated relaxation pressure (IRP) was also studied.
resultsThere were 14 patients from 179 awake manometry procedures that required the sedation or the endoscopy assistance. The mean age was 60.7 years and there was equal gender distribution. Dysphagia (n = 9) remained the predominant indication for the HRM, followed by the pre-operative evaluation for the esophageal surgery (n = 5). In eight patients, awake manometry failed due to the coiling of the catheter above the EGJ and six patients were intolerant to awake catheter insertion technique. Six patients were diagnosed with achalasia and two with EGJ obstruction. The correction of the possible 10% inflation of the IRP did not alter the final diagnosis in majority except one patient with the EGJ obstruction. The findings of the barium esophagogram corroborated the manometry diagnosis.
conclusionEsophageal HRM should be done in awake state as much as possible. Sedation may be a feasible option as against aborting the further workup in patients who fail with current techniques involving awake catheter insertion. However, one needs to be mindful of sedation effects on manometry parameters and interpret results carefully.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.