Evidence map›Paper›PMID 31232550›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2019

[Device and method for evaluating the performance of dry electrode for fabric surface bioelectricity].

Sha Li, Mingyuan Jiang, Jun Xie, Yao Hu, Hao Liu

Abstract read
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. [An antennal electric signal detection system based on template matching].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sha LiSchool of Mechanical Engineering, Tianjin Polytechnic University, Tianjin 300387, P.R.China;Institute of Smart Wearable Electronic Textiles, Tianjin Polytechnic University, Tianjin 300387, P.R.China.
Mingyuan JiangSchool of Mechanical Engineering, Tianjin Polytechnic University, Tianjin 300387, P.R.China;Institute of Smart Wearable Electronic Textiles, Tianjin Polytechnic University, Tianjin 300387, P.R.China.
Jun XieSchool of Mechanical Engineering, Tianjin Polytechnic University, Tianjin 300387, P.R.China;Institute of Smart Wearable Electronic Textiles, Tianjin Polytechnic University, Tianjin 300387, P.R.China.
Yao HuShool of Textiles, Tianjin Polytechnic University, Tianjin 300387, P.R.China;Institute of Smart Wearable Electronic Textiles, Tianjin Polytechnic University, Tianjin 300387, P.R.China.
Hao LiuShool of Textiles, Tianjin Polytechnic University, Tianjin 300387, P.R.China;Institute of Smart Wearable Electronic Textiles, Tianjin Polytechnic University, Tianjin 300387, P.R.China.liuhao@tjpu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In order to quantitatively evaluate the performance of dry electrode for fabric surface bioelectricity, a set of active measuring devices that can simulate electrocardiosignal has been developed on the basis of passive system by our group. Five Ag/AgCl fabric dry electrodes were selected to test and evaluate the devices. The results show that the deviation ratios of peak time interval of the five electrodes are all less than 1%. The maximum voltage amplitude decay rate is 7.2%, and the noise amplitudes are lower than 0.004 mV. The variable coefficient of peak time offset is less than 8%. The variable coefficient of voltage amplitude is less than 2%. The variable coefficient of noise amplitude is less than 10%. Research shows the devices has good repeatability and stability in measuring the simulated electrocardiosignal. The active measuring devices proposed in this paper can provide a new method for performance evaluation and standard formulation of surface bioelectricity dry electrode.

Indexed as

ElectrodesTextilesWearable Electronic Devicesactive measurementdry electrodeelectrocardiosignalfabric

Identifiers

PMID31232550
PMCPMC9929979

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.