Evidence map›Paper›PMID 31230182›Full record

ArticleMagma (New York, N.Y.)2019

Automatic correction of background phase offset in 4D-flow of great vessels and of the heart in MRI using a third-order surface model.

Damian Craiem, Ariel F Pascaner, Mariano E Casciaro, Umit Gencer, Joaquin Alcibar, Gilles Soulat, Elie Mousseaux

Abstract read
PubMed Publisher
In one paragraph

Article in Magma (New York, N.Y.), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.5field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Abdominal applications of quantitative 4D flow MRI.Abdominal radiology (New York) · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Damian CraiemInstituto de Medicina Traslacional, Trasplante y Bioingeniería (IMeTTyB), Universidad Favaloro-CONICET, Solis 453, CP 1078, Buenos Aires, Argentina. dcraiem@favaloro.edu.ar.ORCID http://orcid.org/0000-0003-1065-799X
Ariel F PascanerInstituto de Medicina Traslacional, Trasplante y Bioingeniería (IMeTTyB), Universidad Favaloro-CONICET, Solis 453, CP 1078, Buenos Aires, Argentina.
Mariano E CasciaroInstituto de Medicina Traslacional, Trasplante y Bioingeniería (IMeTTyB), Universidad Favaloro-CONICET, Solis 453, CP 1078, Buenos Aires, Argentina.
Umit GencerCardiovascular Imaging Unit, Hôpital Européen Georges Pompidou, INSERM U970, Paris, France.
Joaquin AlcibarInstituto de Medicina Traslacional, Trasplante y Bioingeniería (IMeTTyB), Universidad Favaloro-CONICET, Solis 453, CP 1078, Buenos Aires, Argentina.
Gilles SoulatCardiovascular Imaging Unit, Hôpital Européen Georges Pompidou, INSERM U970, Paris, France.
Elie MousseauxCardiovascular Imaging Unit, Hôpital Européen Georges Pompidou, INSERM U970, Paris, France.
Consejo Nacional de Investigaciones Científicas y Técnicas · ARInserm · FR

Funding

Consejo Nacional de Innovación, Ciencia y Tecnología PIP 1220130100480Secretaria de Ciencia y Tecnica, Universidad de Buenos Aires PICT 2016-0945
6 · The paper itself

Abstract

objectiveTo evaluate an automatic correction method for velocity offset errors in cardiac 4D-flow acquisitions. MATERIALS AND

methodsVelocity offset correction was done in a plane-by-plane scheme and compared to a volumetric approach. Stationary regions were automatically detected. In vitro experiments were conducted in a phantom using two orientations and two encoding velocities (Venc). First- to third-order models were fit to the time-averaged images of the three velocity components. In vivo experiments included realistic ROIs in a volunteer superimposed to a phantom. In 15 volunteers, blood flow volume of the proximal and distal descending aorta, of the pulmonary artery (Qp) and the ascending aorta (Qs) was compared.

resultsOffset errors were reduced after correction with a third-order model, yielding residual phantom velocities below 0.6 cm/s and 0.4% of Venc. The plane-by-plane correction method was more effective than the volumetric approach. Mean velocities through superimposed ROIs of a volunteer vs phantom were highly correlated (r DISCUSSION: An automatic third-order model corrected velocity offset errors in 4D-flow acquisitions, achieving acceptable levels for clinical applications.

Indexed as

Magnetic Resonance ImagingAdolescentAdultAlgorithmsAorta, AbdominalAorta, ThoracicElectrocardiographyFemaleHealthy VolunteersHeartHemodynamicsHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMaleMiddle AgedBlood flowEddy currentsPhase-contrast MRIVelocity offset error

Identifiers

PMID31230182
OpenAlexW2952315096

What OpenQuestion holds

Textmetadata
Read underepoch 390