Evidence map›Paper›PMID 31228776›Full record

ArticleInternational journal of surgery case reports2019

The use of self-gripping mesh with anterior component separation technique in incisional hernia repair: A case series.

Rintaro Fukuda, Shingo Tsujinaka, Ryo Maemoto, Tsutomu Takenami, Nobuyuki Toyama, Toshiki Rikiyama

Open access · goldAbstract read
In one paragraph

Article in International journal of surgery case reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Rintaro FukudaDepartment of Surgery, Saitama Medical Center, Jichi Medical University, Saitama, Japan. Electronic address: r-fukuda@jichi.ac.jp.
Shingo TsujinakaDepartment of Surgery, Saitama Medical Center, Jichi Medical University, Saitama, Japan. Electronic address: tsujinakas@omiya.jichi.ac.jp.
Ryo MaemotoDepartment of Surgery, Saitama Medical Center, Jichi Medical University, Saitama, Japan. Electronic address: maemoto@jichi.ac.jp.
Tsutomu TakenamiDepartment of Surgery, Saitama Medical Center, Jichi Medical University, Saitama, Japan. Electronic address: takenami@surg.med.tohoku.ac.jp.
Nobuyuki ToyamaDepartment of Surgery, Saitama Medical Center, Jichi Medical University, Saitama, Japan. Electronic address: ntoyama@omiya.jichi.ac.jp.
Toshiki RikiyamaDepartment of Surgery, Saitama Medical Center, Jichi Medical University, Saitama, Japan. Electronic address: trikiyama@jichi.ac.jp.
Jichi Medical University · JPJichi Medical University Saitama Medical Center · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIncisional hernia (IH) is a common postoperative complication that affects 10% of the patients who undergo abdominal surgery. The component separation (CS) technique is suitable for large and/or complex hernias; however, CS alone may not eliminate recurrence and is associated with an increased incidence of wound complications. Self-gripping mesh enhances tissue adhesion and contributes to a reduced risk of migration, chronic pain, and other complications. Here, we present three cases of IH that were successfully repaired by anterior CS (ACS) using onlay self-gripping meshes. CASE PRESENTATION: All three patients underwent surgery using the following technique: Briefly, a skin flap was created with release of the external oblique muscle and preservation of the perforating vessels. The linea alba was closed with absorbable interrupted sutures. A self-gripping mesh was trimmed and placed with a 4-5 cm overlap bilaterally from the closed linea alba using an onlay technique. For all patients, the postoperative courses were uneventful and there were no complications at the 3-month follow-up. DISCUSSION: The advantages of our technique include more sufficient abdominal reinforcement, technical simplicity, and minimal time required for mesh placement. The disadvantages are the potential risk of decreased blood flow of the skin flaps, wound infection, intestinal fistula, persisting or chronic pain, and difficulty with subsequent abdominal surgery.

conclusionThe use of self-gripping mesh with ACS can be performed without increasing the operative time or causing short-term surgical complications. This technique may be recommended for large IH because of its simplicity and secure abdominal reinforcement provided.

Indexed as

Component separation techniqueIncisional herniaSelf-gripping mesh

Identifiers

PMID31228776
PMCPMC6597497
OpenAlexW2952908740

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.