ArticleEuropean radiology2019
Estimation of the radiation dose in pregnancy: an automated patient-specific model using convolutional neural networks.
Article in European radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 20 citations in OpenAlex.
- The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images.BMC medical imaging · 2026Article
- AI-enhanced patient-specific dosimetry in I-131 planar imaging with a single oblique view.Scientific reports · 2025Article
- Standard SPECT myocardial perfusion estimation from half-time acquisitions using deep convolutional residual neural networks.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
- Whole-body voxel-based internal dosimetry using deep learning.European journal of nuclear medicine and molecular imaging · 2021Article
- Stylized versus voxel phantoms: a juxtaposition of organ depth distributions.Physics in medicine and biology · 2020Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 3 countries.
Funding
Abstract
objectivesThe conceptus dose during diagnostic imaging procedures for pregnant patients raises health concerns owing to the high radiosensitivity of the developing embryo/fetus. The aim of this work is to develop a methodology for automated construction of patient-specific computational phantoms based on actual patient CT images to enable accurate estimation of conceptus dose.
methodsWe developed a 3D deep convolutional network algorithm for automated segmentation of CT images to build realistic computational phantoms. The neural network architecture consists of analysis and synthesis paths with four resolution levels each, trained on manually labeled CT scans of six identified anatomical structures. Thirty-two CT exams were augmented to 128 datasets and randomly split into 80%/20% for training/testing. The absorbed doses for six segmented organs/tissues from abdominal CT scans were estimated using Monte Carlo calculations. The resulting radiation doses were then compared between the computational models generated using automated segmentation and manual segmentation, serving as reference.
resultsThe Dice similarity coefficient for identified internal organs between manual segmentation and automated segmentation results varies from 0.92 to 0.98 while the mean Hausdorff distance for the uterus is 16.1 mm. The mean absorbed dose for the uterus is 2.9 mGy whereas the mean organ dose differences between manual and automated segmentation techniques are 0.07%, - 0.45%, - 1.55%, - 0.48%, - 0.12%, and 0.28% for the kidney, liver, lung, skeleton, uterus, and total body, respectively.
conclusionThe proposed methodology allows automated construction of realistic computational models that can be exploited to estimate patient-specific organ radiation doses from radiological imaging procedures. KEY POINTS: • The conceptus dose during diagnostic radiology and nuclear medicine imaging procedures for pregnant patients raises health concerns owing to the high radiosensitivity of the developing embryo/fetus. • The proposed methodology allows automated construction of realistic computational models that can be exploited to estimate patient-specific organ radiation doses from radiological imaging procedures. • The dosimetric results can be used for the risk-benefit analysis of radiation hazards to conceptus from diagnostic imaging procedures, thus guiding the decision-making process.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials