Evidence map›Paper›PMID 31227853›Full record

Trial reportInternational orthopaedics2019

Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial.

Elhadi Sariali, Charles Kajetanek, Yves Catonné

Abstract readComparative StudyRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in International orthopaedics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Elhadi SarialiHôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, AP-HP, F-75013, Paris, France. hedisari@yahoo.fr.ORCID 0000-0003-2634-2466
Charles KajetanekHôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, AP-HP, F-75013, Paris, France.
Yves CatonnéHôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, AP-HP, F-75013, Paris, France.
Sorbonne Université · FRCentre National de la Recherche Scientifique · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIncorrect positioning of components during total knee arthroplasty (TKA) increases the risk of pain, instability, and early revision. The purpose of this study was to compare 3D planning-assisted and a conventional system for TKA positioning. We hypothesized that the use of three-dimensional CT-scan planning and custom cutting guides would increase the accuracy of component positioning.

methodsA randomized, controlled, prospective study of two groups was performed. In one group, patient-specific custom cutting guides (PSCG) were used for component positioning based on 3D CT-scan planning. In the control group, TKA was performed with a conventional ancillary system. The components' positioning angles were measured on 3D reconstructions. The main evaluation criterion was the percentage of outliers outside of a target zone of ± 3° for the coronal positioning of the femoral component.

resultsEighty patients were included. The percentage of outliers for the femoral component was significantly lower in the 3D-guided group (1 patient) compared to the control group (7 patients p = 0.02). The coronal femoral angle was restored with greater accuracy in the 3D-assisted group (- 0.1° ± 1.4°) compared to the control group (1.6° ± 2.5°). Surgery was significantly shorter in the 3D group. The clinical outcomes were better in the 3D group at the two year follow-up with fewer failures and a lower standard deviation in IKS scores.

conclusionThe use of a 3D planning and custom guides can improve TKA component positioning by increasing the accuracy of implants alignment and reducing the percentage of outliers. The same benefit was not demonstrated for the global knee alignment and the clinical scores with no indisputable clinical advantage for the PSCG.

Indexed as

AgedArthritisArthroplasty, Replacement, KneeBone MalalignmentFemaleHumansImaging, Three-DimensionalKnee JointKnee ProsthesisMaleMiddle AgedProspective StudiesSurgery, Computer-AssistedTomography, X-Ray Computed3D planningArthroplastyCustomKneePatient specific

Identifiers

PMID31227853
OpenAlexW2950351190

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.