ArticleJournal of applied clinical medical physics2019
On the need for tuning the dosimetric leaf gap for stereotactic treatment plans in the Eclipse treatment planning system.
Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 42 citations in OpenAlex.
- Dose accuracy evaluation of multi-leaf collimator modeling in single-isocenter multi-target stereotactic radiosurgery.Physics and imaging in radiation oncology · 2026Article
- Multi-institutional study on the commissioning and clinical implementation of the TrueBeam enhanced leaf model in the Eclipse treatment planning system.Journal of applied clinical medical physics · 2025Article
- Optimizing dosimetric leaf gap parameters for radiation therapy: A comparative study using three diode-array verification tools and an ionization chamber.Journal of applied clinical medical physics · 2025Article
- A Time-Series Approach for Machine Learning-Based Patient-Specific Quality Assurance of Radiosurgery Plans.Bioengineering (Basel, Switzerland) · 2025Article
- Evaluation of the accuracy of an enhanced MLC leaf model for Linac-based stereotactic radiosurgery.Journal of applied clinical medical physics · 2025Article
- Developing reference plans for evaluating global clinical trials credentialing and PSQA systems.Journal of applied clinical medical physics · 2025Article
- A novel protocol for parametrization of a beam model for small stereotactic beams.Journal of applied clinical medical physics · 2025Article
- Comprehensive plan quality assessment of simplified volumetric-modulated arc therapy for lung stereotactic body radiotherapy.Radiological physics and technology · 2025Article
- Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation.Journal of applied clinical medical physics · 2025Article
- Impact of enhanced leaf model on dose calculation accuracy in single-isocenter multitarget stereotactic radiosurgery treatments.Journal of applied clinical medical physics · 2025Article
- Machine learning and lean six sigma for targeted patient-specific quality assurance of volumetric modulated arc therapy plans.Physics and imaging in radiation oncology · 2024Article
- A radiotherapy community data-driven approach to determine which complexity metrics best predict the impact of atypical TPS beam modeling on clinical dose calculation accuracy.Journal of applied clinical medical physics · 2024Article
- Impact of MLC error on dose distribution in SRS treatment of single-isocenter multiple brain metastases: comparison between DCAT and VMAT techniques.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2024Article
- Improving the modelling of a multi-leaf collimator with tilted leaf sides used in radiotherapy.Physics and imaging in radiation oncology · 2024Article
- Evaluation of plan complexity and dosimetric plan quality of total marrow and lymphoid irradiation using volumetric modulated arc therapy.Journal of applied clinical medical physics · 2023Article
- Effect of plan complexity on the dosimetry, delivery accuracy, and interplay effect in lung VMAT SBRT with 6 MV FFF beam.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2022Article
- Evaluation of Plan Robustness Using Hybrid Intensity-Modulated Radiotherapy (IMRT) and Volumetric Arc Modulation Radiotherapy (VMAT) for Left-Sided Breast Cancer.Bioengineering (Basel, Switzerland) · 2022Article
- Investigation of Halcyon multi-leaf collimator model in Eclipse treatment planning system: A focus on the VMAT dose calculation with the Acuros XB algorithm.Journal of applied clinical medical physics · 2022Article
- Single isocenter SRS using CAVMAT offers improved robustness to commissioning and treatment delivery uncertainty compared to VMAT.Journal of applied clinical medical physics · 2021Article
- Optimizing the effective spot size and the dosimetric leaf gap of the AcurosXB algorithm for VMAT treatment planning.Journal of applied clinical medical physics · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The dosimetric leaf gap (DLG) and tongue-and-groove (T&G) effects are critical aspects in the modeling of multileaf collimators (MLC) in the treatment planning system (TPS). In this study, we investigated the dosimetric impact of limitations associated with the T&G modeling in stereotactic plans and its relationship with the need for tuning the DLG in the Eclipse TPS. Measurements were carried out using Varian TrueBeam STx systems from two different institutions. Test fields presenting MLC patterns with several MLC gap sizes (meanGap) and different amounts of T&G effect (TGi) were first evaluated. Secondly, dynamic conformal arc (DCA) and volumetric modulated arc therapy (VMAT) deliveries of stereotactic cases were analyzed in terms of meanGap and TGi. Two DLG values were used in the TPS: the measured DLG (DLG