ArticleJournal of medical systems2019
Medical Image Enhancement by a Bilateral Filter Using Optimization Technique.
Article in Journal of medical systems, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Channel-Boosted and Transfer Learning Convolutional Neural Network-Based Osteoporosis Detection from CT Scan, Dual X-Ray, and X-Ray Images.Journal of healthcare engineering · 2024Article
- Fuzzy Gray Level Difference Histogram Equalization for Medical Image Enhancement.Journal of medical systems · 2020Article
Corrections and comments
- Retraction · 2022-05-11Concerns/Issues about Referencing/Attributions · Compromised Peer Review · Rogue Editor · Unreliable Results and/or Conclusions ·
- Retracted
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
For researchers, denoising of Magnetic Resonance (MR) image is a greatest challenge in digital image processing. In this paper, the impulse noise and Rician noise in the medical MR images are removed by using Bilateral Filter (BF). The novel approaches are presented in this paper; Enhanced grasshopper optimization algorithm (EGOA) is used to optimize the BF parameters. To simulate the medical MR images (with different variances), the impulse and Rician noises are added. The EGOA is applied to the noisy image in searching regions of window size, spatial and intensity domain to obtain the filter parameters optimally. The PSNR is taken as fitness value for optimization. We examined the proposed technique results with other MR images After the optimal parameters assurance. In order to comprehend the BF parameters selection importance, the results of proposed denoising method is contrasted with other previously used BFs, genetic algorithm (GA), gravitational search algorithm (GSA) using the quality metrics such as signal-to-noise ratio (SNR), structural similarity index metric (SSIM), mean squared error (MSE), and PSNR. The outcome shows that the EOGA method with BF shows good results than the earlier methods in both edge preservation and noise elimination from medical MR images. The experimental results demonstrate the performance of the proposed method with the accuracy, computational time, and maximum deviation, Peak Signal to Noise Ratio (PSNR), MSE, SSIM, and entropy values of MR images over the existing methods.
Indexed as
Identifiers
31222510What OpenQuestion holds
Registered trials