Evidence map›Paper›PMID 31216639›Full record

ArticleMaterials (Basel, Switzerland)2019

Evaluation of the Accuracy of Four Digital Methods by Linear and Volumetric Analysis of Dental Impressions.

Stefano Pagano, Michele Moretti, Roberto Marsili, Alessandro Ricci, Giancarlo Barraco, Stefano Cianetti

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. [Research progress of digital occlusion setup in orthognathic surgery].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023
    Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Stefano PaganoDepartment of Biomedical and Surgical Sciences, Odontostomatological University Centre, University of Perugia, 06128 Perugia, Italy. stefano.pagano@unipg.it.
Michele MorettiDepartment of Engineering, University of Perugia, via G. Duranti, 93 06128 Perugia, Italy. michele.moretti@unipg.it.ORCID 0000-0003-1532-0413
Roberto MarsiliDepartment of Engineering, University of Perugia, via G. Duranti, 93 06128 Perugia, Italy. roberto.marsili@unipg.it.ORCID 0000-0002-9364-5873
Alessandro Ricci3DIFIC, 06128 Perugia, Italy. alessandro.ricci@edific.it.
Giancarlo BarracoDepartment of Biomedical and Surgical Sciences, Odontostomatological University Centre, University of Perugia, 06128 Perugia, Italy. misure@unipg.it.
Stefano CianettiDepartment of Biomedical and Surgical Sciences, Odontostomatological University Centre, University of Perugia, 06128 Perugia, Italy. stefano.cianetti@unipg.it.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The quality of dental arch impression has a substantial role in the precision of the intervention. It is traditionally acquired with resins that solidify when in contact with the air. Compared to that method, digital impression gives great advantages and, together with three-dimensional (3D) digitization devices, allows a simplification of the digital impression process. The growing adoption of such systems by a large number of dental clinics determines the need for an in-depth evaluation of the accuracy and the precision of the different systems. The aim of this work is to define a methodology for the evaluation of the accuracy and precision of 3D intraoral and desktop scanning systems, by using volumetric and linear methods. The replica of a tooth was realized with zirconium; afterward, high-accuracy point clouds of the master model were acquired by a coordinate measurement machine (CMM). In this way, the dimensions of the replica were accurately known. An intraoral scanner (I) and three desktops (D1, D2, D3) were then used to scan the replica. The geometry resulting from the CMM was compared with the ones derived from the scanners, using two different commercial programs (Geomagic and 3-Matic) and a custom-developed algorithm (MATLAB). Geomagic showed the mean values to be in a range from 0.0286 mm (D1) to 0.1654 mm (I), while 3-Matic showed mean values from -0.0396 mm (D1) to 0.1303 mm (I). MATLAB results ranged from 0.00014 mm (D1) to 0.00049 mm (D2). The probability distributions of the volumetric error of the measurements obtained with the different scanners allow a direct comparison of their performances. For the results given by our study, the volumetric approach that we adopted appears to be an excellent system of analysis.

Indexed as

intraoral scannerspoint cloud registrationvolumetric error distribution

Identifiers

PMID31216639
PMCPMC6631156

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked