ArticleJournal of neural engineering2019
A microfabricated, 3D-sharpened silicon shuttle for insertion of flexible electrode arrays through dura mater into brain.
Article in Journal of neural engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
28 citing papers in PubMed.
- Repeatable, low-drift recordings in behaving nonhuman primates using flexible microelectrodes.Nature communications · 2026Article
- A Drive-Vibration Integrated Piezoelectric Actuator for Flexible Electrode Implantation.Micromachines · 2026Article
- Systematic evaluation of surgical insertion of flexible neural probe arrays into deeper brain targets using length modulation methods.Journal of neural engineering · 2026Article
- Biological and Mechanical Limitations for Chronic Fast-Scan Cyclic Voltammetry Sensor Design.Advanced materials technologies · 2025Article
- Amorphous silicon carbide probe mechanics for insertion in the cerebral cortex of rats, pigs, and macaques.Journal of neural engineering · 2025Article
- Flexible 3D Kirigami Probes for In Vitro and In Vivo Neural Applications.Advanced materials (Deerfield Beach, Fla.) · 2025Article
- Design considerations for optogenetic applications of soft micro-LED-based device systems across diverse nervous systems.Bioactive materials · 2025Review
- Chronic implantable flexible serpentine probe reveals impaired spatial coding of place cells in epilepsy.National science review · 2025Article
- Cracking modes and force dynamics in the insertion of neural probes into hydrogel brain phantom.Journal of neural engineering · 2024Article
- Shape-changing electrode array for minimally invasive large-scale intracranial brain activity mapping.Nature communications · 2024Article
- Multilayer Arrays for Neurotechnology Applications (MANTA): Chronically Stable Thin-Film Intracortical Implants.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023Article
- A mosquito mouthpart-like bionic neural probe.Microsystems & nanoengineering · 2023Article
- Implantable intracortical microelectrodes: reviewing the present with a focus on the future.Microsystems & nanoengineering · 2023Review
- Longitudinal neural and vascular recovery following ultraflexible neural electrode implantation in aged mice.Biomaterials · 2022Article
- Chronic co-implantation of ultraflexible neural electrodes and a cranial window.Neurophotonics · 2022Article
- Insertion mechanics of amorphous SiC ultra-micro scale neural probes.Journal of neural engineering · 2022Article
- Research Progress on the Flexibility of an Implantable Neural Microelectrode.Micromachines · 2022Review
- A silk-based self-adaptive flexible opto-electro neural probe.Microsystems & nanoengineering · 2022Article
- The Future of Neuroscience: Flexible and Wireless Implantable Neural Electronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021Review
- A comparison of insertion methods for surgical placement of penetrating neural interfaces.Journal of neural engineering · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
Abstract
objectiveElectrode arrays for chronic implantation in the brain are a critical technology in both neuroscience and medicine. Recently, flexible, thin-film polymer electrode arrays have shown promise in facilitating stable, single-unit recordings spanning months in rats. While array flexibility enhances integration with neural tissue, it also requires removal of the dura mater, the tough membrane surrounding the brain, and temporary bracing to penetrate the brain parenchyma. Durotomy increases brain swelling, vascular damage, and surgical time. Insertion using a bracing shuttle results in additional vascular damage and brain compression, which increase with device diameter; while a higher-diameter shuttle will have a higher critical load and more likely penetrate dura, it will damage more brain parenchyma and vasculature. One way to penetrate the intact dura and limit tissue compression without increasing shuttle diameter is to reduce the force required for insertion by sharpening the shuttle tip. APPROACH: We describe a novel design and fabrication process to create silicon insertion shuttles that are sharp in three dimensions and can penetrate rat dura, for faster, easier, and less damaging implantation of polymer arrays. Sharpened profiles are obtained by reflowing patterned photoresist, then transferring its sloped profile to silicon with dry etches. MAIN
resultsWe demonstrate that sharpened shuttles can reliably implant polymer probes through dura to yield high quality single unit and local field potential recordings for at least 95 days. On insertion directly through dura, tissue compression is minimal. SIGNIFICANCE: This is the first demonstration of a rat dural-penetrating array for chronic recording. This device obviates the need for a durotomy, reducing surgical time and risk of damage to the blood-brain barrier. This is an improvement to state-of-the-art flexible polymer electrode arrays that facilitates their implantation, particularly in multi-site recording experiments. This sharpening process can also be integrated into silicon electrode array fabrication.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.