ArticlePloS one2019
Tungsten filled 3D printed field shaping devices for electron beam radiation therapy.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- A Target-Specific, "Eco-Friendly" Experimental Setup for Small Field Proton Irradiation.International journal of particle therapy · 2026Article
- A Review of 3D-Printed Medical Devices for Cancer Radiation Therapy.Bioengineering (Basel, Switzerland) · 2026Review
- 3D printed collimators and dosimetry for spatially fractionated radiation therapy.Journal of applied clinical medical physics · 2026Article
- Optical Automatic Contour Tracing (O-ACT) - A novel optical image-guided contour tracing method for electron beam shaping.Medical physics · 2025Article
- Multi-Institutional Audit of FLASH and Conventional Dosimetry With a 3D Printed Anatomically Realistic Mouse Phantom.International journal of radiation oncology, biology, physics · 2024Article
- A clinical solution for non-toxic 3D-printed photon blocks in external beam radiation therapy.Journal of applied clinical medical physics · 2024Article
- Clinical Linear Accelerator-Based Electron FLASH: Pathway for Practical Translation to FLASH Clinical Trials.International journal of radiation oncology, biology, physics · 2023Article
- Shaping success: clinical implementation of a 3D-printed electron cutout program in external beam radiation therapy.Frontiers in oncology · 2023Article
- Transitioning to Environmentally Sustainable, Climate-Smart Radiation Oncology Care.International journal of radiation oncology, biology, physics · 2022Article
- Three-dimensional printers applied for the production of beam blocks in total body irradiation treatment.Journal of applied clinical medical physics · 2022Article
- Nontoxic electron collimators.Journal of applied clinical medical physics · 2021Article
- Additive manufacturing (3D printing) in superficial brachytherapy.Journal of contemporary brachytherapy · 2021Article
- CT-less electron radiotherapy simulation and planning with a consumer 3D camera.Journal of applied clinical medical physics · 2021Article
- Technical report: 3D-printed patient-specific scalp shield for hair preservation in total skin electron beam therapy.Technical innovations & patient support in radiation oncology · 2021Article
- Patient-Specific Quality Assurance Using a 3D-Printed Chest Phantom for Intraoperative Radiotherapy in Breast Cancer.Frontiers in oncology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeElectron radiotherapy is a labor-intensive treatment option that is complicated by the need for field shaping blocks. These blocks are typically made from casting Cerrobend alloys containing lead and cadmium. This is a highly toxic process with limited precision. This work aims to provide streamlined and more precise electron radiotherapy by 3D using printing techniques.
methodsThe 3D printed electron cutout consists of plastic shells filled with 2 mm diameter tungsten ball bearings. Five clinical Cerrobend defined field were compared to the planned fields by measuring the light field edge when mounted in the electron applicator on a linear accelerator. The dose transmitted through the 3D printed and Cerrobend cutouts was measured using an IC profiler ion chamber array with 6 MeV and 16 MeV beams. Dose profiles from the treatment planning system were also compared to the measured dose profiles. Centering and full width half maximum (FWHM) metrics were taken directly from the profiler software.
resultsThe transmission of a 16MeV beam through a 12 mm thick layer of tungsten ball bearings agreed within 1% of a 15 mm thick Cerrobend block (measured with an ion chamber array). The radiation fields shaped by ball bearing filled 3D printed cutout were centered within 0.4 mm of the planned outline, whereas the Cerrobend cutout fields had shift errors of 1-3 mm, and shape errors of 0.5-2 mm. The average shift of Cerrobend cutouts was 2.3 mm compared to the planned fields (n = 5). Beam penumbra of the 3D printed cutouts was found to be equivalent to the 15 mm thick Cerrobend cutout. The beam profiles agreed within 1.2% across the whole 30 cm profile widths.
conclusionsThis study demonstrates that with a proper quality assurance procedure, 3D-printed cutouts can provide more accurate electron radiotherapy with reduced toxicity compared to traditional Cerrobend methods.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials