ArticleActa orthopaedica2019
Uncemented monoblock trabecular metal posterior stabilized high-flex total knee arthroplasty: similar pattern of migration to the cruciate-retaining design - a prospective radiostereometric analysis (RSA) and clinical evaluation of 40 patients (49 knees) 60 years or younger with 9 years' follow-up.
Article in Acta orthopaedica, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04017533 (In Vivo Stability of an Uncemented Total Knee Arthroplasty With Medially Stabilized Design), which is not on this map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
In Vivo Stability of an Uncemented Total Knee Arthroplasty With Medially Stabilized Design
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.
- 6-month migration sufficient for evaluation of total knee replacements: a systematic review and meta-analysis.Acta orthopaedica · 2023Pooled it
- Long-term migration of monoblock vs modular design in uncemented total knee arthroplasty: a secondary report of a randomized trial using radiostereometric analysis.Acta orthopaedica · 2025Trial
- Randomized Controlled Trial of a Novel Cementless vs. Cemented Total Knee Arthroplasty: Early Clinical and Radiographic Outcomes.Orthopaedic surgery · 2024Trial
- Effect of Proprioception and Balance Training Combined with Continuous Nursing on BBS Score and HSS Score of Patients Undergoing Total Knee Arthroplasty.Computational and mathematical methods in medicine · 2022Trial
- Article
- Increased risk of aseptic loosening for posterior stabilized compared with posterior cruciate-retaining uncemented total knee replacements: a cohort study of 13,667 knees from the Dutch Arthroplasty Registry.Acta orthopaedica · 2023Article
- Outcomes of trabecular metal total ankle replacement: a longitudinal observational cohort study of 239 consecutive cases from the Swedish Ankle Registry.Acta orthopaedica · 2022Observational
- Early migration of a medially stabilized total knee arthroplasty : a radiostereometric analysis study up to two years.Bone & joint open · 2021Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and purpose - Uncemented monoblock cruciate retaining (CR) trabecular metal (TM) tibial components in total knee arthroplasty (TKA) work well in the long-term perspective in patients ≤ 60 years. Younger persons expect nearly normal knee flexion after TKA, but CR implants generally achieve less knee flexion compared with posterior stabilized (PS) implants. Cemented PS implants have higher revision rate than CR implants. Can an uncemented monoblock PS TM implant be used safely in younger patients? Patients and methods - 40 patients (49 knees) age ≤ 60 years with primary (20 knees) or posttraumatic osteoarthritis (OA) were operated with a high-flex TKA using an uncemented monoblock PS TM tibial component. Knees were evaluated with radiostereometric analysis (RSA) a mean 3 days (1-5) postoperatively, and thereafter at 6 weeks, 3 months, 1, 2, 5, and 9 years. Clinical outcome was measured with patient-related outcome measures (PROMs). Results - The implants showed a pattern of migration with initial large migration followed by early stabilization lasting up to 9 years, a pattern known to be compatible with good long-term results. Clinical and radiological outcome was excellent with 38 of the 40 patients being satisfied or very satisfied with the procedure and bone apposition to the entire implant surface in 46 of 49 knees. Mean knee flexion was 130°. 1 knee was revised at 3 months due to medial tibial condyle collapse. Interpretation - The uncemented monoblock PS TM implant works well in younger persons operated with TKA due to primary or secondary OA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.