ArticleJournal of applied clinical medical physics2019

Characterizing mechanical and medical imaging properties of polyvinyl chloride-based tissue-mimicking materials.

Yaoyao He, Shengxue Qin, Brandon A Dyer, Hongbin Zhang, Lifen Zhao, Tiao Chen, Fenglian Zheng, Yong Sun, Liting Shi, Yi Rong and 1 more

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Phantoms for use in optical coherence elastography.Journal of biomedical optics · 2026
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yaoyao HeMedical engineering and technology center, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China.
Shengxue QinCollege of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao, China.
Brandon A DyerDepartment of Radiation Oncology, University of California Davis Medical Center, Sacramento, CA, USA.
Hongbin ZhangCollege of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao, China.
Lifen ZhaoSchool of Material Science and Engineering, Shandong University of Science and Technology, Qingdao, China.
Tiao ChenMedical engineering and technology center, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China.
Fenglian ZhengMedical engineering and technology center, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China.
Yong SunRadiology Department, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China.
Liting ShiMedical engineering and technology center, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China.
Yi RongDepartment of Radiation Oncology, University of California Davis Medical Center, Sacramento, CA, USA.
Jianfeng QiuMedical engineering and technology center, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China.

Funding

China National Key Research and Development Program 2016YFC0103400Shandong Province Key Research and Development Program 2017GSF218075Taishan Scholars Program of Shandong Province TS201712065
6 · The paper itself

Abstract

Polyvinyl chloride (PVC) is a commonly used tissue-mimicking material (TMM) for phantom construction using 3D printing technology. PVC-based TMMs consist of a mixture of PVC powder and dioctyl terephthalate as a softener. In order to allow the clinical use of a PVC-based phantom use across CT and magnetic resonance imaging (MRI) imaging platforms, we evaluated the mechanical and physical imaging characteristics of ten PVC samples. The samples were made with different PVC-softener ratios to optimize phantom bioequivalence with physiologic human tissue. Phantom imaging characteristics, including computed tomography (CT) number, MRI relaxation time, and mechanical properties (e.g., Poisson's ratio and elastic modulus) were quantified. CT number varied over a range of approximately -10 to 110 HU. The relaxation times of the T1-weighted and T2-weighted images were 206.81 ± 17.50 and 20.22 ± 5.74 ms, respectively. Tensile testing was performed to evaluate mechanical properties on the three PVC samples that were closest to human tissue. The elastic moduli for these samples ranged 7.000-12.376 MPa, and Poisson's ratios were 0.604-0.644. After physical and imaging characterization of the various PVC-based phantoms, we successfully produced a bioequivalent phantom compatible with multimodal imaging platforms for machine calibration and image optimization/benchmarking. By combining PVC with 3D printing technologies, it is possible to construct imaging phantoms simulating human anatomies with tissue equivalency.

Indexed as

Phantoms, ImagingRadiography, ThoracicHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingMultimodal ImagingPolyvinyl ChlorideTomography, X-Ray ComputedPolyvinyl Chloride3D printingelastic modulusmultimodalityphantompolyvinyl chloride

Identifiers

PMID31207035
PMCPMC6612694

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.