ArticleNeuroradiology2019
Safety and efficacy of intracranial aneurysm embolization using the "combined remodeling technique": low-profile stents delivered through double lumen balloons: a multicenter experience.
Article in Neuroradiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Article
- LVIS EVO stent-through-balloon after hydrocoil embolization of intracranial aneurysms: One-year results.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024Observational
- Safety and Efficacy of LVIS Jr Stent-assisted Coiling of Intracranial Aneurysms in Small-diameter Parent Arteries : A Single-center Experience.Clinical neuroradiology · 2024Article
- Use of the Neuroform Atlas Stent or LVIS Jr Stent for Treatment of Unruptured Intracranial Aneurysms in Parent Arteries of <2 mm in Diameter: A Multicenter Experience.AJNR. American journal of neuroradiology · 2024Article
- Deployment of low-profile flow-diverter through a double lumen balloon catheter (remo-diversion technique) to treat recurrent middle cerebral artery bifurcation aneurysm: A technical note.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024Article
- Double-Balloon-Assisted Coiling for Wide-Necked Posterior Communicating Artery Aneurysms with a Fetal-Type Variant of the Posterior Cerebral Artery: A Case Series.Neurointervention · 2022Article
- Endovascular treatment of aneurysms of the paraophthalmic segment of the internal carotid artery: Current status.Frontiers in neurology · 2022Review
- First multicenter experience using the Silk Vista flow diverter in 60 consecutive intracranial aneurysms: technical aspects.Journal of neurointerventional surgery · 2021Article
- Single Center Experience of the Balloon-Stent Technique for the Treatment of Unruptured Distal Internal Carotid Artery Aneurysms: Sharing a Simple and Reliable Tip to Use Scepter-Atlas Combination.Taehan Yongsang Uihakhoe chi · 2021Article
- Strut remodeling with hypercompliant balloon: A new approach to Y stent-assisted coil embolization in the treatment of complex wide-neck bifurcation aneurysms.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2021Article
- Balloon-assisted coiling of intracranial aneurysms using the Eclipse 2L double lumen balloon.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeSince appearance of the balloon-remodeling technique and stent-assisted coiling, complex aneurysms have been treated successfully by endovascular means worldwide. Although these two techniques have been widely proven, the combination of both traditionally made the procedures more complicated technically. The aim of our study was to determine the technical success, safety, and efficacy of the low-profile stents delivered through double lumen balloons.
methodsClinical, procedural, and angiographic data were analyzed.
resultsEighty-four patients (55 women; age range 20-81 years) harboring 86 aneurysms were included in this study. Aneurysm maximal diameter ranged from 2 to 26 mm, with mean 7.5 mm. There were 62 unruptured, 15 recanalized, and 9 acutely ruptured aneurysms. Aneurysm locations were ACoA (31), MCA (36), supraclinoid ICA (4), carotid bifurcation (2), basilar (7), PCA (3), PICA (2), and VA (1). Ninety-three devices were implanted (63 LVIS jr, 15 LEO Baby, 14 ACCLINO Flex and 1 Neuroform Atlas) through the double lumen balloons (Scepter C or XC and Eclipse 2 L). We found 2 minor clinical events (2.4%) and 1 major event (1.2%). Total intra-procedural technical complication rate was 11.6%. Follow-up was available for 71 patients with an average follow-up of 7 months. Complete and near complete occlusion was 90.1%. Residual aneurysms were seen in 9.9%.
conclusionThe "combined remodeling technique" with low-profile stents delivered through double-lumen balloons is technically feasible, safe, and effective for the treatment of intracranial aneurysms. This technique allows the operator to avoid extra maneuvers.
Indexed as
Identifiers
31203413What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.