ArticleBMC oral health2019
Influence of margin location and luting material on the amount of undetected cement excess on CAD/CAM implant abutments and cement-retained zirconia crowns: an in-vitro study.
Article in BMC oral health, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 33 citations in OpenAlex.
- Clinical performance of a conometric retention system for single implant restorations: 1-year analysis of a prospective multicenter study.International journal of implant dentistry · 2026Article
- Tensile Retention of Lithium Disilicate and Zirconia Crowns Cemented to One-Piece Zirconia Implants: A Pilot In Vitro Study of Cementation Protocol, Resin Cement, and Micro-CT Cement Morphology.Materials (Basel, Switzerland) · 2026Article
- Dental Luting Cements and Peri-Implantitis: Molecular Mechanisms, Clinical Implications and the Role of Autophagy and Nanotechnology-A Narrative Review.Dentistry journal · 2026Review
- Effect of Crown Design, Cement Type and Margin Depth on the Removal of Cement Remnants Around Single Implant-Supported Restorations. An In-Vitro Study.Clinical oral implants research · 2026Article
- Effect of emergence profile and space gap size on excess cement in cement-retained implant reconstructions.Journal of advanced periodontology & implant dentistry · 2025Article
- In vitro fracture resistance of implant-supported terminal zirconia cantilevered frameworks.European oral research · 2025Article
- Cross-sectional analysis comparing prefabricated titanium to individualized hybrid zirconia abutments for cemented zirconia based fixed dental prostheses: a critical concept assessment.International journal of implant dentistry · 2024Article
- Influence of buccal and palatal bone thickness on post-surgical marginal bone changes around implants placed in posterior maxilla: a multi-centre prospective study.BMC oral health · 2023Article
- Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments.The journal of advanced prosthodontics · 2022Article
- Clinical decision-making of anterior implant abutment.Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2022Article
- Selection of 1-mm venting or 2.5-mm screw access holes on implant crowns based on cement extrusion and retention capacity.BMC oral health · 2022Article
- Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China.Patient preference and adherence · 2022Article
- In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns.International journal of implant dentistry · 2021Article
- Qualitative and Semi-Quantitative Assessment of Processing-Related Surface Contamination of One- and Two-Piece CAD/CAM Abutments before and after Ultrasonic Cleaning.Materials (Basel, Switzerland) · 2020Article
- Artificial intelligence in fixed implant prosthodontics: a retrospective study of 106 implant-supported monolithic zirconia crowns inserted in the posterior jaws of 90 patients.BMC oral health · 2020Article
- Correlation between Buccal Bone Thickness at Implant Placement in Healed Sites and Buccal Soft Tissue Maturation Pattern: A Prospective Three-Year Study.Materials (Basel, Switzerland) · 2020Article
- Zirconia crowns cemented on titanium bars using CAD/CAM: a five-year follow-up prospective clinical study of 9 patients.BMC oral health · 2019Article
- Effects of cementless fixation of implant prosthesis: A finite element study.The journal of advanced prosthodontics · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe flexibility in designing the submucosal part of CAD/CAM customized implant abutments and the individual positioning of its shoulder line has been suggested to reduce the risk of leaving undetected cement residues, thus preventing adverse effects on peri-implant tissues. A high correlation between excess cement left in the soft tissues and the occurrence of increased biofilm accumulation with sulcular bleeding and/ or suppuration has been reported. This in turn may cause peri-implant inflammation and peri-implant marginal bone loss. The aim of this study was to assess the frequency of cement remnants after the luting of zirconia crowns on CAD/CAM custom molar abutments with different margin levels and to evaluate the impact of the luting material. MATERIAL AND
methodsA total of 20 titanium molar CAD/CAM implant abutments (BEGO Medical GmbH) with internal taper connection/ internal hex anti-rotation protection, and a convex emergence profile with different margin positions (0, 1, 2 and 3 mm below the mucosa), were virtually designed (Implant Studio, 3Shape) and manufactured. A master cast was scanned, duplicated by a 3D printer and individual gingival masks were produced to simulate peri-implant soft tissues. 20 corresponding zirconia crowns were designed (Cerec 3D, Dentsply Sirona), produced and cemented to the abutments with two different luting materials; a zinc oxide non-eugenol cement (Temp Bond NE) or a methacrylate cement (Panavia V5). To ensure retrievability of the crown/abutment connection, occlusal openings providing access to the abutment screws were designed. Excess cement was thoroughly removed and the crown/abutment units were unscrewed to evaluate the occurrence of cement residues. All the quadrants of each specimen were evaluated for calculation of the ratio between the cement remnant area and the total specimen area using Adobe Photoshop. Spearman analysis was performed to detect correlations between different variables. A two-sided t-test, ANOVA, Mann-Whitney, and Kruskal-Wallis tests were applied to detect differences between the groups.
resultsCement remnants were found in every depth of the crown abutment complex and in almost every area investigated. The amount of cement residues increased as the crown-abutment margin was located more submucosally. Lingual areas were more prone to cement remnants than other surface areas (p = 0.0291). Excess cement was not only found at the margins of the crown-abutment complex, but also underneath (basal) the abutment itself, where cleaning was impossible. No statistical difference in the effect of zinc oxide non-eugenol- and methacrylate cement on the frequency of excess material at the lateral abutment surfaces could be demonstrated in vitro. The proportion of basal abutment aspects covered with cement residues was, however, significantly smaller in Panavia V5 samples with an average of 4.9 ± 3.7% compared to Temp Bond samples with an average of 8.6 ± 5.5%.
conclusionsGiven the results obtained in the present investigation the margin of CAD/CAM molar abutments should be located as coronally as possible to minimize the amount of cement remnants. If an epigingival or supragingival margin location is not feasible due to esthetic concerns, it cannot be recommended to place the margin of molar CAD/CAM abutments deeper than 1.5 mm in the proximal and oral regions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials