Evidence map›Paper›PMID 31197181›Full record

ArticleScientific reports2019

A rapid method for measuring serum oxidized albumin in a rat model of proteinuria and hypertension.

Beibei Liu, Keiko Yasukawa, Suang Suang Koid, Alimila Yeerbolati, Latapati Reheman, Conghui Wang, Yutaka Yatomi, Tatsuo Shimosawa

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.2field-weighted citation impact, top 58% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Oxidized Albumin as a Mediator of Kidney Disease.Antioxidants (Basel, Switzerland) · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Beibei LiuDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Keiko YasukawaDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Suang Suang KoidDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Alimila YeerbolatiDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Latapati RehemanDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Conghui WangDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Yutaka YatomiDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Tatsuo ShimosawaDepartment of Clinical Laboratory, International University of Health and Welfare School of Medicine, Chiba, Japan. tshimo-tky@umin.ac.jp.ORCID http://orcid.org/0000-0002-8742-5129
University of Tokyo Hospital · JPInternational University of Health and Welfare · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Oxidative stress is a risk for and cause of various disease, however, measurements of oxidative stress are either time-consuming or non-specific. Here, we established a rapid method of using high performance liquid chromatography (HPLC) to measure serum oxidized albumin in a rat model. We optimized HPLC conditions for rat oxidized albumin. To validate our method, three-week-old male Sprague-Dawley rats were uninephrectomized and treated normal diet, high salt diet or high salt diet with Tempol, a superoxide dismutase (SOD) mimetic. After 4 weeks of treatment, we analyzed serum oxidized albumin. The main findings are listed as below. (i) Our method of oxidized albumin measurement only takes 16 minutes, with an intra-day and inter-day deviation within 1% and a detection limit concentration of 6.4 mg/ml. (ii) Oxidized albumin levels were significantly higher in the high salt diet group than in the normal salt diet group, and this effect was reversed by Tempol. (iii) Oxidized albumin levels also correlated with urinary protein and 8-isoprostane levels. In conclusion, we have established a simple method for evaluating rat serum oxidized albumin using HPLC. Our method is rapid and has an advantage over conventional methods and may be useful for animal models of oxidative stress.

Indexed as

AlbuminsAnimalsBiochemistryChromatography, High Pressure LiquidDisease Models, AnimalHypertensionMaleOxidation-ReductionProteinuriaRats, Sprague-DawleyReproducibility of ResultsAlbumins

Identifiers

PMID31197181
PMCPMC6565692
OpenAlexW2953060870

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.