Evaluation of the Clinitek®, a point-of-care urinalysis system for the measurement of clinically significant urinary metabolites and detection of haematuria in Schistosoma haematobium infected children in southern Côte d'Ivoire.
Article in Parasites & vectors, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 3 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 3 countries.
Funding
Abstract
backgroundUrinary schistosomiasis, caused by Schistosoma haematobium, remains a significant public health problem worldwide, despite years of efforts to control it. Haematuria is one of the notable indirect indicators of S. haematobium infection and is commonly assessed along with other routine screens using a urinary dipstick test. A portable "field friendly" electronic analyser would offer an automated and thus more objective read-out compared to visual-read dipstick methods.
methodsWithin the framework of a Phase 2 praziquantel dose finding study in preschool- and school-aged children infected with S. haematobium, in southern Côte d'Ivoire, we compared a visual-read of the urine dipstick strips (Multistix PRO, Siemens Healthcare Diagnostics) to an automated reader (CLINITEK Status+ analyser™ Siemens Healthcare Diagnostics). Urine samples were collected from 148 pre-school aged and 152 school-aged children for urinalysis. Values were compared using a linear weighted kappa statistic and Bland-Altman analysis.
resultsA very good correlation between the two methods for nitrites and haematuria was observed (κ coefficient of 0.88 and 0.82, respectively), while a good correlation was observed for leukocytes (κ coefficient of 0.63) A moderate to fair correlation was calculated (κ coefficient ≤ 0.6) for all other parameters. When the results were stratified according to infection intensity, the agreements were stronger from the high infection intensity sample measurements, for most of the parameters.
conclusionOur results demonstrate the device's utility in detecting haematuria and nitrites but underline the need for further development of this tool in order to improve its performance in the field.