ArticleRadiology and oncology2019
The use of high-frequency short bipolar pulses in cisplatin electrochemotherapy in vitro.
Article in Radiology and oncology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 35 citations in OpenAlex.
- Minimization of Cancellation Effect with Nisin During Bipolar Nanosecond Electrochemotherapy.International journal of molecular sciences · 2026Article
- Threshold Interphase Delay for Bipolar Pulses to Prevent Cancellation Phenomenon during Electrochemotherapy.International journal of molecular sciences · 2024Article
- The equivalence of different types of electric pulses for electrochemotherapy with cisplatin - anRadiology and oncology · 2024Article
- Electrochemotherapy for head and neck cancers: possibilities and limitations.Frontiers in oncology · 2024Review
- The Effects of Interphase and Interpulse Delays and Pulse Widths on Induced Muscle Contractions, Pain and Therapeutic Efficacy in Electroporation-Based Therapies.Journal of cardiovascular development and disease · 2023Article
- Article
- Immunogenic Cell Death in Electroporation-Based Therapies Depends on Pulse Waveform Characteristics.Vaccines · 2023Article
- Muscle contractions and pain sensation accompanying high-frequency electroporation pulses.Scientific reports · 2022Article
- Does the shape of the electric pulse matter in electroporation?Frontiers in oncology · 2022Review
- Reduction of muscle contraction and pain in electroporation-based treatments: An overview.World journal of clinical oncology · 2021Article
- Analysis of damage-associated molecular pattern molecules due to electroporation of cells in vitro.Radiology and oncology · 2020Article
- Image Analysis of 3D Conjunctival Melanoma Cell Cultures Following Electrochemotherapy.Biomedicines · 2020Article
- Short microsecond pulses achieve homogeneous electroporation of elongated biological cells irrespective of their orientation in electric field.Scientific reports · 2020Article
- Recent Advances in Electrochemotherapy.Bioelectricity · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background In electrochemotherapy (ECT), chemotherapeutics are first administered, followed by short 100 μs monopolar pulses. However, these pulses cause pain and muscle contractions. It is thus necessary to administer muscle relaxants, general anesthesia and synchronize pulses with the heart rhythm of the patient, which makes the treatment more complex. It was suggested in ablation with irreversible electroporation, that bursts of short high-frequency bipolar pulses could alleviate these problems. Therefore, we designed our study to verify if it is possible to use high-frequency bipolar pulses (HF-EP pulses) in electrochemotherapy. Materials and methods We performed in vitro experiments on mouse skin melanoma (B16-F1) cells by adding 1-330 μM cisplatin and delivering either (a) eight 100 μs long monopolar pulses, 0.4-1.2 kV/cm, 1 Hz (ECT pulses) or (b) eight bursts at 1 Hz, consisting of 50 bipolar pulses. One bipolar pulse consisted of a series of 1 μs long positive and 1 μs long negative pulse (0.5-5 kV/cm) with a 1 μs delay in-between. Results With both types of pulses, the combination of electric pulses and cisplatin was more efficient in killing cells than cisplatin or electric pulses only. However, we needed to apply a higher electric field in HF-EP (3 kV/cm) than in ECT (1.2 kV/cm) to obtain comparable cytotoxicity. Conclusions It is possible to use HF-EP in electrochemotherapy; however, at the expense of applying higher electric fields than in classical ECT. The results obtained, nevertheless, offer an evidence that HF-EP could be used in electrochemotherapy with potentially alleviated muscle contractions and pain.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.