ArticleJournal of neuroengineering and rehabilitation2019
Long-term outcomes of semi-implantable functional electrical stimulation for central drop foot.
Article in Journal of neuroengineering and rehabilitation, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it.
- The Effect of Implanted Functional Electrical Stimulation on Gait Performance in Stroke Survivors: A Systematic Review.Sensors (Basel, Switzerland) · 2021Pooled it
- Functional Electrical Stimulation (FES) in Adults with Neurological Disorders and Foot Drop: Orthotic and Therapeutic Effects in Short- and Long-Term Users.Bioengineering (Basel, Switzerland) · 2026Article
- The effect of electromyographic feedback functional electrical stimulation on the plantar pressure in stroke patients with foot drop.Frontiers in neuroscience · 2024Article
- Implanted Peroneal Nerve Stimulator Treatment for Drop Foot Caused by Central Nervous System Lesion: A Twelve-Month Follow-up of 21 Patients.Journal of rehabilitation medicine · 2022Article
- Useful functional recovery and quality of life after surgical treatment of peroneal nerve injuries.Frontiers in surgery · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCentral drop foot is a common problem in patients with stroke or multiple sclerosis (MS). For decades, it has been treated with orthotic devices, keeping the ankle in a fixed position. It has been shown recently that semi-implantable functional electrical stimulation (siFES) of the peroneal nerve can lead to a greater gait velocity increase than orthotic devices immediately after being switched on. Little is known, however, about long-term outcomes over 12 months, and the relationship between quality of life (QoL) and gait speed using siFES has never been reported applying a validated tool. We provide here a report of short (3 months) and long-term (12 months) outcomes for gait speed and QoL.
methodsForty-five consecutive patients (91% chronic stroke, 9% MS) with central drop foot received siFES (Actigait®). A 10 m walking test was carried out on day 1 of stimulation (T1), in stimulation ON and OFF conditions, and repeated after 3 (T2) and 12 (T3) months. A 36-item Short Form questionnaire was applied at all three time points.
resultsWe found a main effect of stimulation on both maximum (p < 0.001) and comfortable gait velocity (p < 0.001) and a main effect of time (p = 0.015) only on maximum gait velocity. There were no significant interactions. Mean maximum gait velocity across the three assessment time points was 0.13 m/s greater with stimulation ON than OFF, and mean comfortable gait velocity was 0.083 m/s faster with stimulation ON than OFF. The increase in maximum gait velocity over time was 0.096 m/s, with post hoc testing revealing a significant increase from T1 to T2 (p = 0.012), which was maintained but not significantly further increased at T3. QoL scores showed a main effect of time (p < 0.001), with post hoc testing revealing an increase from T1 to T2 (p < 0.001), which was maintained at T3 (p < 0.001). Finally, overall absolute QoL scores correlated with the absolute maximum and comfortable gait speeds at T2 and T3, and the increase in overall QoL scores correlated with the increase in comfortable gait velocity from T1 to T3. Pain was reduced at T2 (p < 0.001) and was independent of gait speed but correlated with overall QoL (p < 0.001).
conclusionsPeroneal siFES increased maximal and comfortable gait velocity and QoL, with the greatest increase in both over the first three months, which was maintained at one year, suggesting that 3 months is an adequate follow-up time. Pain after 3 months correlated with QoL and was independent of gait velocity, suggesting pain as an independent outcome measure in siFES for drop foot.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials