Dosimetric study of the plan quality and dose to organs at risk on tangential breast treatments using the Halcyon linac.

Everardo Flores-Martinez, Gwe-Ya Kim, Catheryn M Yashar, Laura I Cerviño

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
1.5field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 26 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Everardo Flores-MartinezDepartment of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, CA, USA.
Gwe-Ya KimDepartment of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, CA, USA.
Catheryn M YasharDepartment of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, CA, USA.
Laura I CerviñoDepartment of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, CA, USA.
University of California, San Diego · USUniversity of San Diego · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate the plan quality and doses to the heart, contralateral breast (CB), ipsilateral lung (IL), and contralateral lung (CL) in tangential breast treatments using the Halcyon linac with megavoltage setup fields.

methodsRadiotherapy treatment plans with tangential beams from 25 breast cancer patients previously treated on a C-arm linac were replanned for Halcyon. Thirteen corresponded to right-sided breasts and 12 to left-sided breasts, all with a dose prescription of 50 Gy in 25 fractions. Plans were created with the following setup imaging techniques: low-dose (LD) MVCBCT, high-quality (HQ) MVCBCT, LD-MV and HQ-MV pairs and the imaging dose was included in the plans. Plan quality metric values for the lumpectomy cavity, whole-breast and doses to the organs at risk (OARs) were measured and compared with those from the original plans.

resultsNo significant differences in plan quality were observed between the original and Halcyon plans. An increase in the mean dose (Mean) for all the organs was observed for the Halcyon plans. For right-sided plans, the accumulated Mean over the 25 fractions in the C-arm plans was 0.4 ± 0.3, 0.2 ± 0.2, 5.4 ± 1.3, and 0.1 ± 0.1 Gy for the heart, CB, IL, and CL, respectively, while values in the MVCBCT-LD Halcyon plans were 1.2 ± 0.2, 0.6 ± 0.1, 6.5 ± 1.4, and 0.4 ± 0.1 Gy, respectively. For left-sided treatments, Mean in the original plans was 0.9 ± 0.2, 0.1 ± 0.0, 4.2 ± 1.2, and 0.0 ± 0.0 Gy, while for the MVCBCT-LD Halcyon plans values were 1.9 ± 0.2, 0.6 ± 0.2, 5.1 ± 1.2, and 0.5 ± 0.2 Gy, respectively.

conclusionsPlan quality for breast treatments using Halcyon is similar to the quality for a 6 MV, C-arm plan. For treatments using megavoltage setup fields, the dose contribution to OARs from the imaging fields can be equal or higher than the dose from treatment fields.

Indexed as

Breast NeoplasmsFemaleHeartHumansLungMastectomy, SegmentalOrgans at RiskParticle AcceleratorsPrognosisRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedbreastDose to OARsHalcyonIGRT

Identifiers

PMID31183967
PMCPMC6612683
OpenAlexW2953228700

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.