ArticleMedical physics2019
Multifrequency magnetic particle imaging enabled by a combined passive and active drive field feed-through compensation approach.
Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Open-source device for high sensitivity magnetic particle spectroscopy, relaxometry, and hysteresis loop tracing.The Review of scientific instruments · 2024Article
- Harmonic dependence of thermal magnetic particle imaging.Scientific reports · 2023Article
- iMPI: portable human-sized magnetic particle imaging scanner for real-time endovascular interventions.Scientific reports · 2023Article
- Magnetic Particle Spectroscopy with One-Stage Lock-In Implementation for Magnetic Bioassays with Improved Sensitivities.The journal of physical chemistry. C, Nanomaterials and interfaces · 2021Article
- Vibrational and stochastic resonances in driven nonlinear systems: part 2.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2021Article
- Flow velocity quantification by exploiting the principles of the Doppler effect and magnetic particle imaging.Scientific reports · 2021Article
- Article
- Emerging methods in radiology.Der Radiologe · 2020Review
- Optimization of Drive Parameters for Resolution, Sensitivity and Safety in Magnetic Particle Imaging.IEEE transactions on medical imaging · 2020Article
- AC magnetometry with active stabilization and harmonic suppression for magnetic nanoparticle spectroscopy and thermometry.Journal of applied physics · 2020Article
- Using magnetic particle imaging systems to localize and guide magnetic hyperthermia treatment: tracers, hardware, and future medical applications.Theranostics · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeMagnetic particle imaging (MPI) allows fast imaging of the spatial distribution of superparamagnetic iron-oxide based nanoparticles (SPIONs). Recent research suggests that MPI furthermore promises in-vivo access to environmental parameters of SPIONs as temperature or viscosity. Various medical applications as nanomedicine, stem cell-based therapies or magnetic hyperthermia could benefit from in-vivo multiparameter estimation by MPI. One possible approach to get access to functional parameters is particle excitation at multiple frequencies. To enable the investigation of the mentioned approach, a novel MPI device capable of multifrequency excitation is needed.
methodsMPI usually employs analog band-stop filters to cancel the drive field feed-through, which is magnitudes higher than the particle signal. To enable drive field frequency flexibility over a wide bandwidth, we propose a combined passive and active drive field feed-through compensation approach. This cancellation technique further allows the direct detection of the SPIONs' signal at the fundamental excitation frequency.
resultsA combined feed-through suppression of up to -125 dB is reported, which allows to adjust the drive field frequency from 500 Hz to 20 kHz. Initial spectroscopic measurements and images are shown that demonstrate the concept of multifrequency excitation and prove the imaging capability of the presented scanner. A mean signal-to-noise ratio (SNR) enhancement by the factor of 1.7 was shown when the first harmonic is used for measurement-based image reconstruction compared to when it is omitted.
conclusionsIn this paper, the first one-dimensional multifrequency magnetic particle imaging (mf-MPI) that features adjustable excitation frequencies from 500 Hz to 20 kHz is presented. The device will be used to study the principle of multiparameter estimation by employing multifrequency excitation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials