ArticleBioMed research international2019
Biomechanical Evaluation of Dual Plate Configurations for Femoral Shaft Fracture Fixation.
Article in BioMed research international, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 24 citations in OpenAlex.
- Does dual-plating offer superior stability in complex distal femoral fracture management?Journal of orthopaedic surgery and research · 2026Observational
- Double plate fixation improves stiffness in a comminuted canine scapula fracture gap model compared to single plate fixation.Veterinary surgery : VS · 2026Article
- Sustained BMP-2 delivery via alginate microbeads and polydopamine-coated 3D-Printed PCL/β-TCP scaffold enhances bone regeneration in long bone segmental defects.Journal of orthopaedic translation · 2024Article
- Effect of Plate Configuration in the Primary Stability of Osteotomies and Biological Reconstructions of Femoral Defects: Finite-Element Study.Bioengineering (Basel, Switzerland) · 2024Article
- Biomechanical analysis of combi-hole locking compression plate during fracture healing: A numerical study of screw configuration.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2024Article
- Effect of bone cement augmentation with different configurations of the dual locking plate for femoral allograft fixation: finite element analysis and biomechanical study.Journal of orthopaedic surgery and research · 2023Article
- Effectiveness and Biomechanical Analysis of the Ortho-Bridge System on Femoral Fracture Healing: A Retrospective Analysis.Indian journal of orthopaedics · 2022Article
- Spatial Bridge Locking Fixator versus Traditional Locking Plates in Treating AO/OTA 32-A3.2 Fracture: Finite Element Analysis and Biomechanical Evaluation.Orthopaedic surgery · 2022Article
- Minimally invasive plate osteosynthesis for complex comminuted bone fractures in the Fraser's type II floating knee: a case report.European journal of medical research · 2022Article
- Accurate fixation of complicated comminuted femur fracture with customized LCP referencing a life-size 3D-printed model: a case report.Annals of translational medicine · 2020Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimThis study aimed at comparing the mechanical properties of conventional and locking dual plates in adjacent and orthogonal orientations for the surgical fixation of transverse femoral shaft fractures. It also assessed the failure mechanics after dual adjacent and orthogonal locking plate removal.
methodsThirty-two composite femurs were transversally osteotomized and randomly assigned for fixation with either dual locking or compression plates in an adjacent or orthogonal configuration. Sixteen specimens were preloaded axially to 20 N and single-leg stance loads were simulated. The remaining sixteen constructs were subjected to torsional loads of 10 Nm at a rate of 10 Nm/s in external and internal rotation of the femoral head in relation to the knee. Overall combined rotational stiffness was calculated. Eight different specimens with no osteotomy underwent the same experiments after dual locked plate removal and were tested to failure in combined eccentric axial and torsional modes. Data were statistically processed using a two-tailed
resultsOrthogonal constructs were statistically stiffer in axial loading compared to their adjacent counterparts in both conventional and locking configurations (p<0.001). Dual locking plates provided higher torsional stiffness than conventional ones within each plate orientation (p<0.01). Neither axial/torsional strength nor failure loads differed between constructs that had adjacent or orthogonal dual locking plates instrumented and then removed (p>0.05).
conclusionsIn both orthogonal and adjacent orientations, double locking plates provide higher stability than their dual conventional counterparts. Orthogonal dual plate configuration is more stable and biomechanically superior to dual adjacent plating for constructs fixed with either standard compression or locking plates.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.