Evidence map›Paper›PMID 31183369›Full record

ArticleBioMed research international2019

Biomechanical Evaluation of Dual Plate Configurations for Femoral Shaft Fracture Fixation.

Marc El Beaino, Randal P Morris, Ronald W Lindsey, Zbigniew Gugala

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 24 citations in OpenAlex.

  1. Observational
  2. Article
  3. Article
  4. Article
  5. Biomechanical analysis of combi-hole locking compression plate during fracture healing: A numerical study of screw configuration.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2024
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Marc El BeainoDepartment of Orthopaedic Surgery and Rehabilitation, The University of Texas Medical Branch, Galveston, TX, USA.ORCID 0000-0003-4990-3334
Randal P MorrisDepartment of Orthopaedic Surgery and Rehabilitation, The University of Texas Medical Branch, Galveston, TX, USA.
Ronald W LindseyDepartment of Orthopaedic Surgery and Rehabilitation, The University of Texas Medical Branch, Galveston, TX, USA.
Zbigniew GugalaDepartment of Orthopaedic Surgery and Rehabilitation, The University of Texas Medical Branch, Galveston, TX, USA.ORCID 0000-0003-2331-7660
The University of Texas Medical Branch at Galveston · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimThis study aimed at comparing the mechanical properties of conventional and locking dual plates in adjacent and orthogonal orientations for the surgical fixation of transverse femoral shaft fractures. It also assessed the failure mechanics after dual adjacent and orthogonal locking plate removal.

methodsThirty-two composite femurs were transversally osteotomized and randomly assigned for fixation with either dual locking or compression plates in an adjacent or orthogonal configuration. Sixteen specimens were preloaded axially to 20 N and single-leg stance loads were simulated. The remaining sixteen constructs were subjected to torsional loads of 10 Nm at a rate of 10 Nm/s in external and internal rotation of the femoral head in relation to the knee. Overall combined rotational stiffness was calculated. Eight different specimens with no osteotomy underwent the same experiments after dual locked plate removal and were tested to failure in combined eccentric axial and torsional modes. Data were statistically processed using a two-tailed

resultsOrthogonal constructs were statistically stiffer in axial loading compared to their adjacent counterparts in both conventional and locking configurations (p<0.001). Dual locking plates provided higher torsional stiffness than conventional ones within each plate orientation (p<0.01). Neither axial/torsional strength nor failure loads differed between constructs that had adjacent or orthogonal dual locking plates instrumented and then removed (p>0.05).

conclusionsIn both orthogonal and adjacent orientations, double locking plates provide higher stability than their dual conventional counterparts. Orthogonal dual plate configuration is more stable and biomechanically superior to dual adjacent plating for constructs fixed with either standard compression or locking plates.

Indexed as

Bone PlatesBiomechanical PhenomenaEquipment DesignFemoral FracturesFracture Fixation, InternalHumansWeight-Bearing

Identifiers

PMID31183369
PMCPMC6512036
OpenAlexW2940860864

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.