Evidence map›Paper›PMID 31181688›Full record

Trial reportSensors (Basel, Switzerland)2019

Effect of IMU Design on IMU-Derived Stride Metrics for Running.

Michael V Potter, Lauro V Ojeda, Noel C Perkins, Stephen M Cain

Abstract readClinical Trial
In one paragraph

Trial report in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Estimating Walking Speed in the Wild.Frontiers in sports and active living · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Michael V PotterDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. mvpotter@umich.edu.
Lauro V OjedaDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. lojeda@umich.edu.ORCID 0000-0001-6605-3293
Noel C PerkinsDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. ncp@umich.edu.
Stephen M CainDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. smcain@umich.edu.ORCID 0000-0003-1961-4195

Funding

National Science Foundation DGE 1256260US Army Contracting Command-APG W911QY-15-C-0053
6 · The paper itself

Abstract

Researchers employ foot-mounted inertial measurement units (IMUs) to estimate the three-dimensional trajectory of the feet as well as a rich array of gait parameters. However, the accuracy of those estimates depends critically on the limitations of the accelerometers and angular velocity gyros embedded in the IMU design. In this study, we reveal the effects of accelerometer range, gyro range, and sampling frequency on gait parameters (e.g., distance traveled, stride length, and stride angle) estimated using the zero-velocity update (ZUPT) method. The novelty and contribution of this work are that it: (1) quantifies these effects at mean speeds commensurate with competitive distance running (up to 6.4 m/s); (2) identifies the root causes of inaccurate foot trajectory estimates obtained from the ZUPT method; and (3) offers important engineering recommendations for selecting accurate IMUs for studying human running. The results demonstrate that the accuracy of the estimated gait parameters generally degrades with increased mean running speed and with decreased accelerometer range, gyro range, and sampling frequency. In particular, the saturation of the accelerometer and/or gyro induced during running for some IMU designs may render those designs highly inaccurate for estimating gait parameters.

Indexed as

Wearable Electronic DevicesAdolescentAdultBiosensing TechniquesEquipment DesignFemaleGaitHumansMaleRunningYoung Adultgaitsensor requirementswearable sensorsZUPT

Identifiers

PMID31181688
PMCPMC6603669

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.