Evidence map›Paper›PMID 31179645›Full record

ArticleJournal of applied clinical medical physics2019

Cerebrospinal fluid T1 value phantom reproduction at scan room temperature.

Akihiro Yamashiro, Masato Kobayashi, Takaaki Saito

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. In vivo TMagnetic resonance in medicine · 2022
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

Akihiro YamashiroDepartment of Radiology, Nagano Red Cross Hospital, Nagano-City, Nagano-ken, Japan.
Masato KobayashiDepartment of Radiology, Shinano Town Shin-Etsu Hospital, Kamiminochi-gun, Nagano-ken, Japan.
Takaaki SaitoDepartment of Radiology, Iiyama Red Cross Hospital, Iiyama-City, Nagano-ken, Japan.
Matsuyama Red Cross Hospital · JPNagano Municipal Hospital · JPNagano Red Cross Hospital · JP

Funding

Nagano Red Cross Hospital
6 · The paper itself

Abstract

The T1 value of pure water, which is often used as a phantom to simulate cerebrospinal fluid, is significantly different from that of in-vivo cerebrospinal fluid. The purpose of this study was to develop a phantom with a T1 value equivalent to that of in-vivo cerebrospinal fluid under examination room temperature (23°C-25°C). In this study, 1.5 and 3.0 T magnetic resonance imaging scanners were used. We examined the signal intensity change in relation to pure water temperature, the T1 values of acetone-diluted solutions (0-100 v/v%, in 10 steps), and the correlation coefficients obtained from volunteers and the prepared phantoms. The T1 value was close to the value reported in the literature for cerebrospinal fluid when the acetone-diluted solution was 70 v/v% or higher at scan room temperature. The value at that time was 3532.81-4704.57 ms at 1.5 T and it ranged from 4052.41 to 5701.61 ms at 3.0 T. The highest correlation with the values obtained from the volunteers was r = 0.993 with pure acetone at 1.5 T and r = 0.991 with acetone 90 v/v% at 3.0 T. The relative error of the best phantom-volunteer match was 32.61 (%) ± 6.71 at 1.5 T and 46.67 (%) ± 4.31 at 3.0 T. The T1 value measured by the null point method did not detect a significant difference between in vivo CSF and acetone 100 v/v% at 1.5 T and acetone 90 v/v% at 3.0 T. The T1 value of cerebrospinal fluid in the living body at scan room temperature was reproduced with acetone. The optimum concentration of acetone for cerebrospinal-fluid reproduction was pure acetone at 1.5 T and 90 v/v% at 3.0 T.

Indexed as

Phantoms, ImagingAcetoneAdultCerebrospinal FluidFemaleHeadHealthy VolunteersHumansMagnetic Resonance ImagingMaleMiddle AgedTemperatureYoung AdultAcetoneacetonecerebrospinal fluidphantomrelaxation timeT1 valuetemperature

Identifiers

PMID31179645
PMCPMC6612700
OpenAlexW2950512757

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.