SynthesisJournal of clinical monitoring and computing2020
Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.
Synthesis in Journal of clinical monitoring and computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 37 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
37 citing papers in PubMed, 1 synthesis or guideline pooled it, 94 citations in OpenAlex.
- Accuracy and Trending Ability of Electrical Biosensing Technology for Non-invasive Cardiac Output Monitoring in Neonates: A Systematic Qualitative Review.Frontiers in pediatrics · 2022Pooled it
- Hemodynamic effects of norepinephrine versus phenylephrine infusion for prophylaxis against spinal anesthesia-induced hypotension in the elderly population undergoing hip fracture surgery: a randomized controlled trial.Korean journal of anesthesiology · 2021Trial
- Percutaneous Interventions for Heart Failure in Congenital Heart Disease.Current cardiology reports · 2026Review
- Less-Invasive Hemodynamic and Tissue Perfusion Monitoring in Sepsis and Septic Shock: A Narrative Review.Journal of clinical medicine · 2026Review
- Electrical Cardiometry as a Novel Tool for Assessing Systemic Vascular Resistance and Cardiac Function in Obstructive Sleep Apnea.Journal of clinical medicine · 2026Article
- Ensuring safety of exercise training through non-invasive measurement of cardiac function: A pilot study in adults.Physiological reports · 2026Article
- Use of shunt-side esCCO monitoring for hemodynamic management during hemodialysis as a novel approach for early detection of hypotension: a report of two cases.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2025Article
- Advanced hemodynamic monitoring: feasibility of leveraging non-invasive electrocardiometry in critically ill pediatric patients requiring continuous kidney replacement therapy.Pediatric nephrology (Berlin, Germany) · 2025Observational
- FoCUS and non-invasive hemodynamics monitoring in neonatal sepsis.European journal of pediatrics · 2025Observational
- Perioperative hemodynamic parameters monitored by three noninvasive technologies in children with congenital heart disease: A prospective study.Pediatric discovery · 2025Article
- Electrical cardiometry for non-invasive cardiac output monitoring: a method comparison study in patients after coronary artery bypass graft surgery.Journal of clinical monitoring and computing · 2025Article
- Non-Invasive Cardiac Output Monitoring with Electrical Cardiometry During Laparoscopic Cholecystectomy Surgery, a Cross-Sectional Study.Journal of clinical medicine · 2025Article
- Comparison of noninvasive electrical cardiometry and transpulmonary thermodilution for cardiac output measurement in critically ill patients: a prospective observational study.BMC anesthesiology · 2025Observational
- Effect of different volumes of bupivacaine 0.25% caudal blocks on cardiac index measured by electrical cardiometry in children undergoing elective lower abdominal surgeries: A randomised controlled trial.Indian journal of anaesthesia · 2025Article
- Performance evaluation of non-invasive cardiac output monitoring device (HemoVista) based on multi-channel thoracic impedance plethysmography technology.Acute and critical care · 2024Article
- Hemodynamic monitoring during weaning from mechanical ventilation in critically ill pediatric patients: a prospective observational study.BMC pediatrics · 2024Observational
- Evaluating tissue hypoxia and the response to fluid administration in septic shock patients: a metabolic cluster analysis.BMC anesthesiology · 2024Observational
- Effects of canagliflozin on cardiac remodeling and hemodynamic parameters in patients with type 2 diabetes mellitus.Scientific reports · 2023Observational
- Inferior vena cava ultrasound and other techniques for assessment of intravascular and extravascular volume: an update.Clinical kidney journal · 2023Review
- Perioperative advanced haemodynamic monitoring of patients undergoing multivisceral debulking surgery: an observational pilot study.Intensive care medicine experimental · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Cardiac output monitoring is used in critically ill and high-risk surgical patients. Intermittent pulmonary artery thermodilution and transpulmonary thermodilution, considered the gold standard, are invasive and linked to complications. Therefore, many non-invasive cardiac output devices have been developed and studied. One of those is electrical cardiometry. The results of validation studies are conflicting, which emphasize the need for definitive validation of accuracy and precision. We performed a database search of PubMed, Embase, Web of Science and the Cochrane Library of Clinical Trials to identify studies comparing cardiac output measurement by electrical cardiometry and a reference method. Pooled bias, limits of agreement (LoA) and mean percentage error (MPE) were calculated using a random-effects model. A pooled MPE of less than 30% was considered clinically acceptable. A total of 13 studies in adults (620 patients) and 11 studies in pediatrics (603 patients) were included. For adults, pooled bias was 0.03 L min
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.