Evidence map›Paper›PMID 31175291›Full record

ArticleNature communications2019

Full-field structured-illumination super-resolution X-ray transmission microscopy.

Benedikt Günther, Lorenz Hehn, Christoph Jud, Alexander Hipp, Martin Dierolf, Franz Pfeiffer

Abstract read
In one paragraph

Article in Nature communications, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Quantitative Stain Mapping in X-Ray Virtual Histology.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Benedikt GüntherDepartment of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany. benedikt.guenther@tum.de.
Lorenz HehnDepartment of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany.
Christoph JudDepartment of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany.
Alexander HippHelmholtz-Zentrum Geesthacht, Max-Planck-Str. 1, 21502, Geesthacht, Germany.
Martin DierolfDepartment of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany.ORCID http://orcid.org/0000-0001-5150-2949
Franz PfeifferDepartment of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Modern transmission X-ray microscopy techniques provide very high resolution at low and medium X-ray energies, but suffer from a limited field-of-view. If sub-micrometre resolution is desired, their field-of-view is typically limited to less than one millimetre. Although the field-of-view increases through combining multiple images from adjacent regions of the specimen, so does the required data acquisition time. Here, we present a method for fast full-field super-resolution transmission microscopy by structured illumination of the specimen. This technique is well-suited even for hard X-ray energies above 30 keV, where efficient optics are hard to obtain. Accordingly, investigation of optically thick specimen becomes possible with our method combining a wide field-of-view spanning multiple millimetres, or even centimetres, with sub-micron resolution and hard X-ray energies.

Identifiers

PMID31175291
PMCPMC6555788

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.