Rapid testing of red blood cell parameters in primary care patients using HemoScreen™ point of care instrument.
Article in BMC family practice, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Hemoscreen Point-of-Care Analyzer Compared With Sysmex XN-1000 for Complete Blood Count in Pediatric Inpatients Aged 2 Months to 17 Years.International journal of laboratory hematology · 2026Article
- Clinical Evaluation of a Novel Point-of-Care Hematology Analyzer for Complete Blood Count With Differential.International journal of laboratory hematology · 2026Article
- Home self-testing of complete blood counts in patients with breast cancer during chemotherapy: A proof-of-concept cohort study in e-oncology.Acta oncologica (Stockholm, Sweden) · 2024Article
- Article
- Anemia management in non-menopausal women in a primary care setting: a prospective evaluation of clinical practice.BMC family practice · 2020Observational
- Quantitative absorption imaging of red blood cells to determine physical and mechanical properties.RSC advances · 2020Article
- Point-of-care technologies in heart, lung, blood and sleep disorders from the Center for Advancing Point-of-Care Technologies.Current opinion in biomedical engineering · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPatients with anemia are frequently encountered in primary care. Once anemia is detected, it is essential to define the type and identify the underlying cause prior to initiation of treatment. In most cases, the cause can be determined using information from the patient history, physical exam, and complete blood counts (CBC). Point of care testing of blood cell counts would speed up the work up of anemia patients. The aim of the present study was to evaluate if the HemoScreen™ instrument (PixCell Medical, Yokneam Ilit, Israel) could be used for primary care samples. It is a POCT instrument that utilizes single sample cuvettes and image analysis of full blood count including RBC, Hemoglobin, MCV, MCH, platelets, WBC, and WBC 5-part differential.
methodsWe compared the HemoScreen™ and the Sysmex XN instrument results of 100 primary care patient samples focusing on the total white blood cells, red blood cell parameters RBC, Hemoglobin, MCH, MCV and platelets.
resultsDeming correlations between the HemoScreen™ and the Sysmex XN instruments for the CBC were WBC
conclusionThe HemoScreen™ instrument could provide rapid and accurate test results for evaluation of the red blood cell parameters in primary care. This new technology is interesting as it allows the analysis red blood cell parameters also at small primary care centers.