Evidence map›Paper›PMID 31172229›Full record

ArticlePediatric cardiology2019

Feasibility of Non-invasive Fetal Electrocardiographic Interval Measurement in the Outpatient Clinical Setting.

Ashish N Doshi, Paige Mass, Kevin R Cleary, Jeffrey P Moak, Kiyoe Funamoto, Yoshitaka Kimura, Ahsan H Khandoker, Anita Krishnan

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric cardiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ashish N DoshiDivision of Cardiology, Children's National Health System, 111 Michigan Ave NW, Washington, DC, 20010, USA. adoshi2@jhu.edu.ORCID http://orcid.org/0000-0001-8740-0258
Paige MassSheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Ave NW, Washington, DC, 20010, USA.
Kevin R ClearySheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Ave NW, Washington, DC, 20010, USA.
Jeffrey P MoakDivision of Cardiology, Children's National Health System, 111 Michigan Ave NW, Washington, DC, 20010, USA.
Kiyoe FunamotoAdvanced Interdisciplinary Biomedical Engineering, Tohoku University School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai-shi, Miyagi, 980-8575, Japan.
Yoshitaka KimuraAdvanced Interdisciplinary Biomedical Engineering, Tohoku University School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai-shi, Miyagi, 980-8575, Japan.
Ahsan H KhandokerDepartment of Biomedical Engineering, Khalifa University of Science and Technology, PO Box 127788, Abu Dhabi, United Arab Emirates.ORCID http://orcid.org/0000-0002-0636-1646
Anita KrishnanDivision of Cardiology, Children's National Health System, 111 Michigan Ave NW, Washington, DC, 20010, USA.

Funding

Children's National Cardiology Patient Research Fund SPF 44563
6 · The paper itself

Abstract

Non-invasive fetal electrocardiography (ECG) is a promising method for evaluating fetal cardiac electrical activity. Despite advances in fetal ECG technology, its ability to provide reliable, interpretable results in a typical outpatient fetal cardiology setting remains unclear. We sought to determine the feasibility of measuring standard ECG intervals in an outpatient fetal cardiology practice using an abdominal fetal ECG device that employs blind source separation with reference, an innovative signal-processing technique for fetal ECG extraction. Women scheduled for clinically indicated outpatient fetal echocardiogram underwent 10 min of fetal ECG acquisition from the maternal abdomen using specialized gel electrodes. A bedside laptop computer performed fetal ECG extraction, allowing real-time visualization of fetal and maternal ECG signals. Offline post-processing of 1 min of recorded data yielded fetal P-wave duration, PR interval, QRS duration, RR interval, QT interval, and QTc. Fifty-five fetuses were studied with gestational age 18-37 weeks, including 13 with abnormal fetal echocardiogram findings and three sets of twins. Interpretable results were obtained in 91% of fetuses, including 85% during the vernix period and 100% of twin fetuses. PR interval and RR interval of 18-24 week gestation fetuses were significantly shorter than those with gestational age 25-31 and 32-37 weeks. Of the six fetuses with abnormal rhythms on fetal echocardiogram, fetal ECG tracing was interpretable in five and matched the rhythm noted on fetal echocardiogram. Abdominal fetal ECG acquisition is feasible for arrhythmia detection and ECG interval calculation in a routine clinical setting.

Indexed as

Heart Rate, FetalAdultAmbulatory Care FacilitiesArrhythmias, CardiacElectrocardiographyFeasibility StudiesFemaleGestational AgeHumansMiddle AgedPregnancyPrenatal DiagnosisYoung AdultArrhythmiaElectrocardiogramFetalPrenatal

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.