ArticleIIE transactions on healthcare systems engineering2015
How lapse and slip errors influence head-of-bed angle compliance rates as measured by a portable, wireless data collection system.
Article in IIE transactions on healthcare systems engineering, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Application of a Human Factors Systems Approach to Healthcare Control Centres for Managing Patient Flow: A Scoping Review.Journal of medical systems · 2024Article
- How bedside feedback improves head-of-bed angle compliance for intubated patients.IISE transactions on healthcare systems engineering · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The recommended protocols to prevent ventilator-associated pneumonia include keeping ventilated patients' head and upper body elevated to an angle between 30 and 45 degrees. These recommendations are largely based on a study that has been difficult to replicate, because studies that have attempted to replicate the original conditions have failed to achieve the necessary bed angles consistently. This work suggests the possibility that two specific types of human error, slips and lapses, contribute to non-compliant bed angles. A novel device provided 83,655 samples of bed angles over a period of 1579 hours. The bed angle was out of compliance 64.2% of the time analyzed. Slips, the accident of raising the bed to an angle slightly less than the desired angle, accounted for most of the out-of-compliance measurements, or 55.9% of the time analyzed. It appears that stochastic variation in the bed adjustments results in the bed being out of compliance. Interventions should be investigated such as increasing the target angle and providing feedback at the moment the bed is raised to close to, but less than, the target angle.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.