Evidence map›Paper›PMID 31164579›Full record

ReviewMethods and protocols2018

Review of Biomedical Applications of Contactless Imaging of Neonates Using Infrared Thermography and Beyond.

Abbas K AlZubaidi, Yahya Ethawi, Georg M Schmölzer, Sherif Sherif, Michael Narvey, Molly Seshia

Open access · goldAbstract readReview
In one paragraph

Review in Methods and protocols, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 22 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Abbas K AlZubaidiBiomedical Engineering Division, University of Saskatchewan, Campus Dr 9, Saskatoon, SK S7N 5A5, Canada. aba658@mail.usask.ca.ORCID 0000-0001-6222-5625
Yahya EthawiSection of Neonatology, Winnipeg Regional Health Authority, Winnipeg, MB R3B 1E2, Canada. yethawi@hsc.mb.ca.
Georg M SchmölzerSection of Neonatology, Department of Pediatrics, University of Alberta, Edmonton, AB T6G 1C9, Canada. georg.schmoelzer@me.com.ORCID 0000-0001-9798-2415
Sherif SherifDepartment of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada. Sherif.Sherif@umanitoba.ca.
Michael NarveySection of Neonatology, Winnipeg Regional Health Authority, Winnipeg, MB R3B 1E2, Canada. mnarvey@hsc.mb.ca.
Molly SeshiaSection of Neonatology, Department of Pediatrics, University of Manitoba, Winnipeg, MB R3A 1S1, Canada. mseshia@hsc.mb.ca.
University of Manitoba · CAWinnipeg Regional Health Authority · CAUniversity of Alberta · CAUniversity of Saskatchewan · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The sick preterm infant monitoring is an intriguing job that medical staff in Neonatal Intensive Care Units (NICU) must deal with on a daily basis. As a standards monitoring procedure, preterm infants are monitored via sensors and electrodes that are firmly attached to their fragile and delicate skin and connected to processing monitors. However, an alternative exists in contactless imaging to record such physiological signals (we call it as Physio-Markers), detecting superficial changes and internal structures activities which can be used independently of, or aligned with, conventional monitors. Countless advantages can be gained from unobtrusive monitoring not limited to: (1) quick data generation; (2) decreasing physical and direct contact with skin, which reduces skin breakdown and minimizes risk of infection; and (3) reduction of electrodes and probes connected to clinical monitors and attached to the skin, which allows greater body surface-area for better care. This review is an attempt to build a solid ground for and to provide a clear perspective of the potential clinical applications of technologies inside NICUs that use contactless imaging modalities such as Visible Light Imaging (VLI), Near Infrared Spectroscopy (NIRS), and Infrared Thermography (IRT).

Indexed as

near-infraredneonatal imagingoptical coherence tomographyphysio-features, infrared thermographypreterm infants, NICUshort-wave infraredtissue opticsvisible light

Identifiers

PMID31164579
PMCPMC6481091
OpenAlexW2898520047

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.