Evidence map›Paper›PMID 31159533›Full record

Trial reportKorean journal of anesthesiology2019

Comparison of Air-QⓇ insertion techniques in pediatric patients with fiber-optic bronchoscopic assessment: a prospective randomized control trial.

Manasa Gaddam, Sameer Sethi, Aditi Jain, Vikas Saini

Open access · goldAbstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in Korean journal of anesthesiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Manasa GaddamDepartment of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Nehru Hospital, Chandigarh, India.
Sameer SethiDepartment of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Nehru Hospital, Chandigarh, India.
Aditi JainDepartment of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Nehru Hospital, Chandigarh, India.
Vikas SainiDepartment of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Nehru Hospital, Chandigarh, India.
Post Graduate Institute of Medical Education and Research · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAir-QⓇ laryngeal mask airway (LMA) is a second-generation supraglottic airway device (SAD) providing adequate airway control despite the unfavorable airway anatomy in children. Several studies have assessed it as a conduit for tracheal intubation and compared its efficacy with that of other SADs, but there are no studies comparing the laryngeal view with midline and rotational insertion techniques of Air-Q. Therefore, this study compared the fiber-optic bronchoscopic (FOB) assessment of the Air-Q position using these two insertion techniques.

methodsThis randomized controlled trial included 80 patients of the American Society of Anesthesiologists physical status I/II of either sex (age group 5-12 years, weight 10-30 kg), who were scheduled for elective surgery in the supine position under general anesthesia. The patients were randomly subjected to rotational and midline technique groups (n = 40, each), and appropriate sized Air-Q, based on the weight of the patient, was inserted using the technique allocated to each patient. Time taken and number of attempts for successful insertion of the devices and any complications after removal of device were studied.

resultsFOB grade 1 (ideal position) was seen in 29/40 (72.5%) and 19/40 (47.5%) children subjected to the rotational and classic midline techniques, respectively (P = 0.045). The time taken to successfully insert the Air-Q was significantly lesser in the rotational technique group (7.2 ± 1.5 s) than in the classic midline technique group (10.2 ± 2.1 s) (P < 0.001), whereas complications were similar in both groups.

conclusionsThe rotational technique was associated with better FOB view, and was faster than the classic midline technique of Air-Q insertion in pediatric patients.

Indexed as

Laryngeal MasksAnesthesia, GeneralBody WeightBronchoscopyChildChild, PreschoolEquipment DesignFemaleFiber Optic TechnologyHumansIntubation, IntratrachealMaleProspective StudiesRotationSupine PositionAir-QⓇComplicationsInsertion techniquesLaryngeal mask airwayLaryngeal viewSupraglottic airway

Identifiers

PMID31159533
PMCPMC6900414
OpenAlexW2948511098

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.