Evidence map›Paper›PMID 31158259›Full record

ArticlePloS one2019

Development, integration and use of an ultra-high-strength gradient system on a human-size 3 T magnet for small animal MRI.

Kuan-Hung Cho, Sheng-Min Huang, Chang-Hoon Choi, Ming-Jye Chen, Hsuan-Han Chiang, Richard P Buschbeck, Ezequiel Farrher, N Jon Shah, Ruslan Garipov, Ching-Ping Chang and 2 more

Abstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Kuan-Hung ChoInstitute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan.ORCID 0000-0001-9267-8342
Sheng-Min HuangInstitute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan.
Chang-Hoon ChoiInstitute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany.ORCID 0000-0003-3569-0905
Ming-Jye ChenInstitute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan.
Hsuan-Han ChiangInstitute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan.
Richard P BuschbeckInstitute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany.ORCID 0000-0001-8201-3937
Ezequiel FarrherInstitute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany.
N Jon ShahInstitute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany.
Ruslan GaripovMR Solutions Ltd., Guildford, United Kingdom.
Ching-Ping ChangDepartment of Medical Research, Chi Mei Medical Center, Tainan, Taiwan.
Hsu ChangInstitute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan.
Li-Wei KuoInstitute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to integrate an ultra-high-strength gradient coil system on a clinical 3 T magnet and demonstrate its preclinical imaging capabilities. Dedicated phantoms were used to qualitatively and quantitatively assess the performance of the gradient system. Advanced MR imaging sequences, including diffusion tensor imaging (DTI) and quantitative susceptibility mapping (QSM), were implemented and executed on an ex vivo specimen as well as in vivo rats. The DTI and QSM results on the phantom agreed well with those in the literature. Furthermore, studies on ex vivo specimens have demonstrated the applicability of DTI and QSM on our system to probe microstructural changes in a mild traumatic brain injury rat model. The feasibility of in vivo rat DTI was also demonstrated. We showed that the inserted ultra-high-strength gradient coil was successfully integrated on a clinically used magnet. After careful tuning and calibration, we verified the accuracy and quantitative preclinical imaging capability of the integrated system in phantom and in vivo rat brain experiments. This study can be essential to establish dedicated animal MRI platform on clinical MRI scanners and facilitate translational studies at clinical settings.

Indexed as

Magnetic Resonance ImagingMagnetsAnimalsBrainBrain Injuries, TraumaticCalibrationDiffusion Tensor ImagingDisease Models, AnimalHumansImage Processing, Computer-AssistedPhantoms, ImagingRatsTime FactorsWaterWater

Identifiers

PMID31158259
PMCPMC6546248

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.