Evidence map›Paper›PMID 31157074›Full record

ArticleEuropean journal of hospital pharmacy : science and practice2018

Chemical and microbiological stability, anticoagulant efficacy and toxicity of 35 and 90 mM trisodium citrate solutions stored in plastic syringes.

Paola Milla, Maria Luisa Viterbo, Sabino Mosca, Silvia Arpicco

Registry-linked trialOpen access · greenAbstract read
In one paragraph

Article in European journal of hospital pharmacy : science and practice, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01639664 (COMPACT), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 99% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01639664 naterminatednot on this map

COMPACT (COMbining Plasma-filtration and Adsorption Clinical Trial): Efficacy and Safety of High Doses CPFA (Coupled Plasma Filtration Adsorption) for Septic Shock in the ICU

TypeinterventionalSponsorGruppo Italiano per la Valutazione degli Interventi in Terapia IntensivaRan2013 to 2017Enrolled115ConditionsShock, SepticArmsHigh doses CPFA
3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Paola MillaDepartment of Drug Science and Technology, University of Turin, Turin, Italy.ORCID 0000-0002-4245-4161
Maria Luisa ViterboHospital Pharmacy, San Giovanni Bosco Hospital, Turin, Italy.
Sabino MoscaDepartment of Anesthesiology and Resuscitation, San Giovanni Bosco Hospital, Turin, Italy.
Silvia ArpiccoDepartment of Drug Science and Technology, University of Turin, Turin, Italy.ORCID 0000-0002-4754-6591
Ospedale San Giovanni Bosco · ITUniversity of Turin · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTrisodium citrate is an interesting alternative to heparin for the prevention of circuit clotting during extracorporeal procedures, but some protocols require non-commercially available citrate concentrations. Little published information is available about the stability of diluted citrate solutions.

objectivesTo evaluate the long-term stability, efficacy and toxicity of 35 mM and 90 mM trisodium citrate solutions prepared by diluting a commercially available sterile solution, stored in plastic syringes and used as an anticoagulant during citrate bag changes in the coupled plasma filtration adsorption (CPFA) technique in the COMPACT-2 clinical trial.

methodsThe chemical stability of trisodium citrate solutions was evaluated by high-performance liquid chromatography after 7, 14, 21 and 28 days of storage. Sterility tests were performed both immediately after preparation and after 28 days of storage.

resultsAfter 28 days of storage, the concentration of trisodium citrate had not changed in comparison with day 1, and both solutions passed the sterility test. A preliminary test indicated that a 35 mM solution is insufficient to ensure an effective anticoagulant action on an extracorporeal circuit, but the 90 mM solution was successfully used for 7 CPFA treatments in 2 patients, without clinical signs of toxicity.

conclusionsBoth the 35 mM and 90 mM solutions are chemically and microbiologically stable for 28 days when stored at room temperature in 50 mL syringes protected by light. The 90 mM solution is an effective and safe regional anticoagulant in the CPFA protocol. TRIAL REGISTRATION NUMBER: NCT01639664.

Indexed as

INTENSIVE & CRITICAL CARELABORATORY / QUALITY CONTROLSTABILITY AND INCOMPATIBILITY

Identifiers

PMID31157074
PMCPMC6319411
OpenAlexW2574825015

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.