Evidence map›Paper›PMID 31156342›Full record

ArticleJournal of medical biochemistry2019

Determining the Need for Repeat Testing of Blood Ethanol Concentration: Evaluation of the Synchron Blood Ethyl Alcohol Assay Kit.

Yasemin Ustundağ, Kağan Huysal, Sevim Eşmedere Eren

Open access · diamondAbstract read
In one paragraph

Article in Journal of medical biochemistry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.1field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Yasemin UstundağDepartment of Clinical Biochemistry, University of Health Sciences, Bursa Yuksek Ihtisas Training and Research Hospital, Bursa 16290, Bursa Turkey.
Kağan HuysalDepartment of Clinical Biochemistry, University of Health Sciences, Bursa Yuksek Ihtisas Training and Research Hospital, Bursa 16290, Bursa Turkey.
Sevim Eşmedere ErenDepartment of Clinical Biochemistry, University of Health Sciences, Bursa Yuksek Ihtisas Training and Research Hospital, Bursa 16290, Bursa Turkey.
Sağlık Bilimleri Üniversitesi · TRBursa Technical University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn clinical laboratories, a common practice used to verify tests prior to reporting is repeat testing. Our objective was to evaluate the differences between the results of blood ethanol concentration (BEC) test repetitions and report on the role of repeat testing to prevent reporting of incorrect results.

methodsWe conducted a retrospective study of data retrieved from the Bursa Yuksek Ihtisas Training and Research Hospital's document management system by calculating the percentage change between repeated BEC test runs. To assess for clinical relevance, the bias between two results from the same sample was compared using the 1988 Clinical Laboratory Improvement Amendments' (CLIA) proficiency testing allowable total error (TEa) limits.

resultsFrom a total of 1,627 BEC tests performed between January 2017 and January 2018, 70% (1,133) were repeat tested. Of these, 830 resulted in BECs between 0-5 mmol/L, of which 237 (28.5%) were above the 25% acceptable TEa. Two hundred seventy-six BEC test results were greater than >14 mmol/L, and there was a good consensus between the initial and repeat test results (99%). In this group, the mean bias was 0.0% (95%, CI = -9.8-9.8%). However, three of the repeat test results were considered significantly different. There were two discordant results in the 5-14 mmol/L ethanol level, and the mean bias was 2.1% (95%, CI = -15.0-19.1%).

conclusionThe majority of the repeated BEC test values were the same as the baseline value; therefore, there may be limited benefit in continuing such frequent repeated analyses.

Indexed as

blood ethanol concentrationrepeat testing

Identifiers

PMID31156342
PMCPMC6534961
OpenAlexW2898902967

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.