ArticleBiomedical optics express2019
Parallel detection of Jones-matrix elements in polarization-sensitive optical coherence tomography.
Article in Biomedical optics express, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 17 citations in OpenAlex.
- Trial
- In Vivo Evaluation of Peripapillary Scleral Architecture in Myopia and Glaucoma Using Polarization-Sensitive Optical Coherence Tomography.Investigative ophthalmology & visual science · 2026Article
- POLARIZATION-SENSITIVE OPTICAL COHERENCE TOMOGRAPHY FEATURES OF THE REPAIR TISSUE AFTER RETINAL PIGMENT EPITHELIUM TEAR AND FUNCTIONAL CORRELATION WITH VISUAL OUTCOMES.Retinal cases & brief reports · 2026Article
- Possible Extension of Inner Scleral Fibers Into the Peripapillary Sclera Detected by Polarization-Sensitive OCT.Investigative ophthalmology & visual science · 2026Article
- Short-term changes in retinal pigment epithelium after anti-vascular endothelial growth factor therapy for neovascular age-related macular degeneration evaluated by polarization-sensitive optical coherence tomography.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026Article
- Characterization of the depolarization contrast line in the outer retina using polarization-sensitive optical coherence tomography.Scientific reports · 2025Article
- Assessment of iris pigment epithelium depolarization and associated factors using polarization-sensitive anterior segment optical coherence tomography.International ophthalmology · 2025Article
- Visualization of CONature chemistry · 2024Article
- Visualization of Anterior Chamber Angle Structures With Scattering- and Polarization-Sensitive Anterior Segment Optical Coherence Tomography.Translational vision science & technology · 2021Article
- Three-Dimensional Distribution Of Fundus Depolarization and Associating Factors Measured Using Polarization-Sensitive Optical Coherence Tomography.Translational vision science & technology · 2021Article
- Imaging of a retinal pigment epithelium aperture using polarization-sensitive optical coherence tomography.Japanese journal of ophthalmology · 2021Article
- Melanin concentration and depolarization metrics measurement by polarization-sensitive optical coherence tomography.Scientific reports · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The polarization properties of a sample can be characterized using a Jones matrix. To measure the Jones matrix without assumptions of the sample, two different incident states of polarization are usually used. This requirement often causes certain drawbacks in polarization-sensitive optical coherence tomography (PS-OCT), e.g., a decrease in the effective A-scan rate or axial depth range, if a multiplexing scheme is used. Because both the A-scan rate and axial depth range are important for clinical applications, including the imaging of an anterior eye segment, a new PS-OCT method that does not have these drawbacks is desired. Here, we present a parallel-detection approach that maintains the same A-scan rate and axial measurement range as conventional OCT. The interferometer consists of fiber-optic components, most of which are polarization-maintaining components with fast-axis blocking free from polarization management. When a parallel detection is implemented using swept-source OCT (SS-OCT), synchronization between the A-scans and synchronization between the detection channels have critical effects on the Jones-matrix measurement. Because it is difficult to achieve perfect synchronization using only hardware, we developed a solution using a numerical correction with signals from a static mirror. Using the developed system, we demonstrate the imaging of an anterior eye segment from the cornea to the back surface of the crystalline lens.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.