ArticleApplied physics letters2019
Numerical modeling of ultrasound heating for the correction of viscous heating artifacts in soft tissue temperature measurements.
Article in Applied physics letters, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 25 citations in OpenAlex.
- A Magnetic Resonance-Compatible Fiberoptic Temperature Sensor for Measuring Focused Ultrasound-Induced Heating Without Artifacts.Ultrasound in medicine & biology · 2026Article
- Imaging of Neurovascular Activity during Motor Responses Evoked by Displacement-guided Focused Ultrasound (DgFUS) Neuromodulation in Mice.Research square · 2026Article
- Millisecond-level transient heating and temperature monitoring technique for ultrasound-induced thermal strain imaging.Theranostics · 2025Article
- Cobalt-doped ZnO nanoparticles and PLD-deposited thin film forms: structure, optical properties and nature of magnetic anisotropy.RSC advances · 2024Article
- Article
- Radiosensitization of Allogenic Subcutaneous C6 Glioma Model with Focused Ultrasound-Induced Mild Hyperthermia.Life (Basel, Switzerland) · 2024Article
- Real-Time Reconstruction of HIFU Focal Temperature Field Based on Deep Learning.BME frontiers · 2024Article
- Synchronous temperature variation monitoring during ultrasound imaging and/or treatment pulse application: a phantom study.IEEE open journal of ultrasonics, ferroelectrics, and frequency control · 2021Article
- Displacement Imaging for Focused Ultrasound Peripheral Nerve Neuromodulation.IEEE transactions on medical imaging · 2020Article
- Image-guided focused ultrasound modulates electrically evoked motor neuronal activity in the mouse peripheral nervous system in vivo.Journal of neural engineering · 2020Article
- Iterative Curve Fitting of the Bioheat Transfer Equation for Thermocouple-Based Temperature Estimation In Vitro and In Vivo.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
Abstract
Measuring temperature during focused ultrasound (FUS) procedures is critical for characterization, calibration, and monitoring to ultimately ensure safety and efficacy. Despite the low cost and the high spatial and temporal resolutions of temperature measurements using thermocouples, the viscous heating (VH) artifact at the thermocouple-tissue interface requires reading corrections for correct thermometric analysis. In this study, a simulation pipeline is proposed to correct the VH artifact arising from temperature measurements using thermocouples in FUS fields. The numerical model consists of simulating a primary source of heating due to ultrasound absorption and a secondary source of heating from viscous forces generated by the thermocouple in the FUS field. Our numerical validation found that up to 90% of the measured temperature rise was due to VH effects. Experimental temperature measurements were performed using thermocouples embedded in fresh chicken breast samples. Temperature corrections were demonstrated for single high-intensity FUS pulses at 3.1 MHz and for multiple pulses (3.1 MHz, 100 Hz, and 500 Hz pulse repetition frequency). The VH accumulated during sonications and produced a temperature increase of 3.1 °C and 15.3 °C for the single and multiple pulse sequences, respectively. The methodology presented here enables the decoupling of the temperature increase generated by absorption and VH. Thus, more reliable temperature measurements can be extracted from thermocouple measurements by correcting for VH.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.