Evidence map›Paper›PMID 31137891›Full record

ArticleBiosensors2019

Perfusion Changes at the Forehead Measured by Photoplethysmography during a Head-Down Tilt Protocol.

Tomas Y Abay, Kamran Shafqat, Panayiotis A Kyriacou

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Wearable Photoplethysmography for Cardiovascular Monitoring.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022
    Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Tomas Y AbayResearch Centre for Biomedical Engineering, University of London, London EC1V 0HB, UK. tomas.ysehak-abay@city.ac.uk.ORCID 0000-0002-9096-7551
Kamran ShafqatResearch Centre for Biomedical Engineering, University of London, London EC1V 0HB, UK. kamran79s@hotmail.com.
Panayiotis A KyriacouResearch Centre for Biomedical Engineering, University of London, London EC1V 0HB, UK. p.kyriacou@city.ac.uk.ORCID 0000-0002-2868-485X
City, University of London · GB

Funding

Barts and The London NHS Trust (Barts Charity) 832/1716
6 · The paper itself

Abstract

Photoplethysmography (PPG) signals from the forehead can be used in pulse oximetry as they are less affected by vasoconstriction compared to fingers. However, the increase in venous blood caused by the positioning of the patient can deteriorate the signals and cause erroneous estimations of the arterial oxygen saturation. To date, there is no method to measure this venous presence under the PPG sensor. This study investigates the feasibility of using PPG signals from the forehead in an effort to estimate relative changes in haemoglobin concentrations that could reveal these posture-induced changes. Two identical reflectance PPG sensors were placed on two different positions on the forehead (above the eyebrow and on top of a large vein) in 16 healthy volunteers during a head-down tilt protocol. Relative changes in oxygenated ( Δ HbO 2 ), reduced ( Δ HHb) and total ( Δ tHb) haemoglobin were estimated from the PPG signals and the trends were compared with reference Near Infrared Spectroscopy (NIRS) measurements. Also, the signals from the two PPG sensors were analysed in order to reveal any difference due to the positioning of the sensor. Δ HbO 2 , Δ HHb and Δ tHb estimated from the forehead PPGs trended well with the same parameters from the reference NIRS. However, placing the sensor over a large vasculature reduces trending against NIRS, introduces biases as well as increases the variability of the changes in Δ HHb. Forehead PPG signals can be used to measure perfusion changes to reveal venous pooling induced by the positioning of the subject. Placing the sensor above the eyebrow and away from large vasculature avoids biases and large variability in the measurements.

Indexed as

Head-Down TiltBiosensing TechniquesForeheadHemoglobinometryHumansPhotoplethysmographyhaemoglobin concentrationshead-down tiltNear Infrared Spectroscopyreflectance photoplethysmographyvenous pooling

Identifiers

PMID31137891
PMCPMC6628167
OpenAlexW2947005341

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.