Evidence map›Paper›PMID 31136438›Full record

Observational studyClinical orthopaedics and related research2019

Do Trabecular Metal Acetabular Components Reduce the Risk of Rerevision After Revision THA Performed for Periprosthetic Joint Infection? A Study Using the NJR Data Set.

Gulraj S Matharu, Andrew Judge, David W Murray, Hemant G Pandit

Open access · greenAbstract readObservational Study
In one paragraph

Observational study in Clinical orthopaedics and related research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Tantalum versus titanium acetabular component in single-stage hip revision for periprosthetic joint infection: a comparative analysis of implant survivorship.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2025
    Article
  3. Article
  4. Article
  5. Review
  6. Recent Advances in Research on Antibacterial Metals and Alloys as Implant Materials.Frontiers in cellular and infection microbiology · 2021
    Review
  7. Observational
  8. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 3 countries.

Gulraj S MatharuG. S. Matharu, A. Judge, D. W. Murray, H. G. Pandit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK G. S. Matharu, A. Judge, Musculoskeletal Research Unit, Department of Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, UK H. G. Pandit, Leeds Institute of Rheumatic and Musculoskeletal Medicine, Chapel Allerton Hospital, Leeds, UK.
Andrew Judge
David W Murray
Hemant G Pandit
Anthera Pharmaceuticals (United States) · USInstitut Universitari d'Investigació en Atenció Primària Jordi Gol · ESRenal Association · GBRoyal College of Surgeons of England · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA single-center study of 144 THAs revised specifically for periprosthetic joint infection (PJI) observed that trabecular metal (TM) acetabular components had a reduced risk of rerevision for subsequent infection compared with non-TM implants. It was suggested that TM was protective against infection after revision and that TM may be useful when revising THAs for PJI. Three registry studies have subsequently assessed the effect of TM on future infection. In the National Joint Registry (NJR) for England and Wales, we earlier reported lower revision rates for infection when TM (versus non-TM) was used in primary THA, but no difference in rerevision rates for infection when TM was used for all-cause revision THAs. The latter findings in all-cause revisions were also confirmed in a study from the Swedish and Australian registries. It is possible that TM only reduces the risk of infection when it is specifically used for PJI revisions (rather than all-causes). However, to date, the registry analyses have not had large enough cohorts of such cases to assess this meaningfully. QUESTIONS/PURPOSES: (1) In revision THAs performed for PJI, are rerevision rates for all-cause acetabular indications lower with TM acetabular components compared with non-TM designs? (2) In revision THAs performed for PJI, are rerevision rates of any component for infection lower with TM acetabular components compared with non-TM designs?

methodsA retrospective observational study was performed using NJR data from England and Wales, which is the world's largest arthroplasty registry and contains details of over two million joint replacement procedures. The registry achieves high levels of patient consent (92%) and linked procedures (ability to link serial procedures performed on the same patient and hip; 94%). Furthermore, recent validation studies have demonstrated that when revision procedures have been captured within the NJR, the data completion and accuracy were excellent. Of 11,988 revisions performed for all causes, 794 were performed for PJI in which the same cementless acetabular component produced by one manufacturer was used. Acetabular components were either TM (n = 541) or non-TM (n = 253). At baseline the two groups were comparable for sex, age, body mass index, and American Society of Anesthesiologists (ASA) grade. Outcomes after revision THA (rerevision for all-cause acetabular indications and rerevision of any component for infection) were compared between the groups using Fine and Gray regression analysis, which considers the competing mortality risk. Regression models were adjusted for the propensity score, with this score summarizing many of the potential patient and surgical confounding factors (age, sex, ASA grade, surgeon grade, approach, and type of revision procedure performed).

resultsThere was no difference in 5-year cumulative acetabular component survival rates between TM (96.3%; 95% confidence interval [CI], 94%-98%) and non-TM components (94.4%, 95% CI, 90%-97%; subhazard ratio, 0.78, 95% CI, 0.37-1.65; p = 0.509). There was no difference in 5-year cumulative implant survival rates free from infection between TM (94.8%; 95% CI, 92%-97%) and non-TM components (94.4%, 95% CI, 90%-97%; subhazard ratio, 0.97, 95% CI, 0.48-1.96; p = 0.942).

conclusionsWe found no evidence to support the notion that TM acetabular components used for PJI revisions reduced the subsequent risk of all-cause rerevision or the risk of rerevision for infection compared with non-TM implants from the same manufacturer. We therefore advise caution against recent claims that TM components may protect against infection. LEVEL OF EVIDENCE: Level III, therapeutic study.

Indexed as

Arthroplasty, Replacement, HipMetal-on-Metal Joint ProsthesesAcetabulumAgedFemaleHumansMaleProsthesis DesignProsthesis-Related InfectionsReoperationRetrospective StudiesSurvival RateUnited Kingdom

Identifiers

PMID31136438
PMCPMC6554127
OpenAlexW2901231659

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.