Evidence map›Paper›PMID 31136429›Full record

ArticleClinical orthopaedics and related research2019

What Factors Are Associated With Neck Fracture in One Commonly Used Bimodular THA Design? A Multicenter, Nationwide Study in Slovenia.

Simon Kovač, Blaž Mavčič, Marko Kotnik, Vesna Levašič, Mateja Sirše, Samo Karel Fokter

Open access · greenAbstract readMulticenter Study
In one paragraph

Article in Clinical orthopaedics and related research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
3.5field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 1 institution in 4 countries.

Simon KovačS. Kovač, V. Levašič, Valdoltra Orthopaedic Hospital, Ankaran, Slovenia B. Mavčič, Department of Orthopaedic Surgery, University Medical Centre Ljubljana, Ljubljana, Slovenia M. Kotnik, Department of Orthopaedics, Celje General Hospital, Celje, Slovenia M. Sirše, S. K. Fokter, Department of Orthopaedics, University Medical Centre Maribor, Maribor, Slovenia.
Blaž Mavčič
Marko Kotnik
Vesna Levašič
Mateja Sirše
Samo Karel Fokter
Prudential Financial (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFemoral stems with bimodular (head-neck as well as neck-body) junctions were designed to help surgeons address patients' hip anatomy individually. However, arthroplasty registers have reported higher revision rates in stems with bimodular junctions than in stems with modularity limited to the head-neck trunnion. However, to our knowledge, no epidemiologic study has identified patient-specific risk factors for modular femoral neck fractures, and some stems using these designs still are produced and marketed. QUESTIONS/PURPOSES: The purposes of this study were (1) to establish the survival rate free from aseptic loosening of one widely used bimodular THA design; (2) to define the proportion of patients who experienced a fracture of the stem's modular femoral neck; and (3) to determine factors associated with neck fracture.

methodsIn this retrospective, nationwide, multicenter study, we reviewed 2767 bimodular Profemur® Z stems from four hospitals in Slovenia with a mean followup of 8 years (range, 3 days to 15 years). Between 2002 and 2015, the four participating hospitals performed 26,132 primary THAs; this implant was used in 2767 of them (11%). The general indications for using this implant were primary osteoarthritis (OA) in 2198 (79%) hips and other indications in 569 (21%) hips. We followed patients from the date of the index operation to the date of death, date of revision, or the end of followup on March 1, 2018. We believe that all revisions would be captured in our sample, except for patients who may have emigrated outside the country, but the proportion of people immigrating to Slovenia is higher than the proportion of those emigrating from it; however, no formal accounting for loss to followup is possible in a study of this design. There were 1438 (52%) stems implanted in female and 1329 (48%) in male patients, respectively. A titanium alloy neck was used in 2489 hips (90%) and a cobalt-chromium neck in 278 (10%) hips. The mean body mass index (BMI) at the time of operation was 29 kg/m (SD ± 5 kg/m). We used Kaplan-Meier analysis to establish survival rates, and we performed a chart review to determine the proportion of patients who experienced femoral neck fractures. A binary logistic regression model that controlled for the potential confounding variables of age, sex, BMI, time since implantation, type of bearing, diagnosis, hospital, neck length, and neck material was used to analyze neck fractures.

resultsThere were 55 (2%) aseptic stem revisions. Survival rate free from aseptic loosening at 12 years was 97% (95% confidence interval [CI] ± 1%). Fracture of the modular neck occurred in 23 patients (0.83%) with a mean BMI of 29 kg/m (SD ± 4 kg/m.) Twenty patients with neck fractures were males and 19 of 23 fractured necks were long. Time since implantation (odds ratio [OR], 0.55; 95% CI 0.46-0.66; p < 0.001), a long neck (OR, 6.77; 95% CI, 2.1-22.2; p = 0.002), a cobalt-chromium alloy neck (OR, 5.7; 95% CI, 1.6-21.1; p = 0.008), younger age (OR, 0.91; 95% CI, 0.86-0.96; p < 0.001), and male sex (OR, 3.98; 95% CI, 1.04-14.55; p = 0.043) were factors associated with neck fracture.

conclusionsThe loosening and neck fracture rates of the Profemur® Z stem were lower than in some of previously published series. However, the use of modular femoral necks in primary THA increases the risk for neck fracture, particularly in young male patients with cobalt-chromium long femoral necks. The bimodular stem we analyzed fractured unacceptably often, especially in younger male patients. For most patients, the risks of using this device outweigh the benefits, and several dozen patients had revisions and complications they would not have had if a different stem had been used. LEVEL OF EVIDENCE: Level III, therapeutic study.

Indexed as

Arthroplasty, Replacement, HipProsthesis FailureChromium AlloysFemaleFemoral Neck FracturesFollow-Up StudiesHip ProsthesisHumansKaplan-Meier EstimateMaleMetal-on-Metal Joint ProsthesesMiddle AgedProsthesis DesignReoperationRetrospective StudiesRisk FactorsChromium AlloysTitanium

Identifiers

PMID31136429
PMCPMC6554145
OpenAlexW2920674025

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.